Simultaneous in vivo detection of spectrally resolved glutamate, glutamine, and glutathione at 3 T with NAA ‐aspartyl editing and echo‐time optimization

Li An iD, Sungtak Hong iD, Tara Turon, Adriana J Pavletic, Christopher S Johnson, Jun Shen

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70076 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2026. Written by Li An and 5 co-authors. Institution: National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland, USA. Major MEDLINE topics: Glutamine, Glutathione, Glutamic Acid, Aspartic Acid. 41 references. The full text is freely available (open access, CC BY 4.0). Funded by: Intramural NIH HHS, NIH HHS, National Institutes of Health.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

To achieve spectrally resolved in vivo detection of glutamate, glutamine, and glutathione at 3 T.

Methods

Difference editing of N‐acetylaspartate CH 2 protons (NAA‐CH 2 ) combined with a new echo‐time (TE) optimization approach is introduced. Difference editing was used to detect NAA‐CH 2 independently of NAA‐CH 3 , thereby eliminating systematic errors arising from constrained fitting of the entire NAA molecule. Numerical optimization of TE and TE 1 minimized interference from highly dominant glutamate in glutamine detection in the ON/OFF sum spectrum. In vivo data were acquired from 6 healthy participants, including 2 who underwent oral administration of [U‐ 13 C]glucose.

Results

The NAA‐aspartyl‐edited, cleaned‐up in vivo spectrum showed distinct separation of glutamate, glutamine, and glutathione peaks at 3 T, facilitating spectral quantification and clinical applications. The post‐ 13 C proton MR‐spectroscopy spectra clearly demonstrated the dynamic 13 C‐labeling of glutamate C4 following oral [U‐ 13 C]glucose intake.

Conclusion

This technique enables simultaneous spectral resolution of glutamate, glutamine, and glutathione peaks at 3 T using difference editing of NAA‐CH 2 and an optimized TE of 85 ms. Additionally, it demonstrates, for the first time, the feasibility of measuring 13 C turnovers of spectrally resolved glutamate at 3 T with the high sensitivity and spatial resolution of proton MR spectroscopy.

Subjects

MeSH terms (MEDLINE)

GlutamineGlutathioneGlutamic AcidAspartic AcidHumansMaleAdultFemaleMagnetic Resonance SpectroscopyBrainAlgorithmsGlucoseProtons

Author keywords

13CNAA‐CH2glutamateglutamineglutathione

Substances

GlutamineGlutathioneGlutamic AcidAspartic AcidN-acetylaspartateGlucoseProtons

Authors and institutions

  • National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland, USA.

ORCID profiles: Li An, Sungtak Hong

Funding

  • Intramural NIH HHS
  • NIH HHS
  • National Institutes of Health

Cite

APA

An, L., Hong, S., Turon, T., Pavletic, A. J., Johnson, C. S., & Shen, J. (2026). Simultaneous in vivo detection of spectrally resolved glutamate, glutamine, and glutathione at 3 T with NAA ‐aspartyl editing and echo‐time optimization. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70076

Vancouver

An L, Hong S, Turon T, Pavletic AJ, Johnson CS, Shen J. Simultaneous in vivo detection of spectrally resolved glutamate, glutamine, and glutathione at 3 T with NAA ‐aspartyl editing and echo‐time optimization. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70076

BibTeX
@article{An2026,
  author = {An, Li and Hong, Sungtak and Turon, Tara and Pavletic, Adriana J and Johnson, Christopher S and Shen, Jun},
  title = {Simultaneous in vivo detection of spectrally resolved glutamate, glutamine, and glutathione at 3 T with NAA ‐aspartyl editing and echo‐time optimization},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70076}
}
Start for free →