Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Minghao Zhang und 1 weiteren Autor:innen. Beteiligte Einrichtung: Wolfson Brain Imaging Centre, University of Cambridge, Cambridge, United Kingdom. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Echo-Planar Imaging. Die Arbeit nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Cambridge Trust, NIHR Cambridge Biomedical Research Centre, Medical Research Council.
Abstract (Originalsprache)
Purpose
Turbo spin echo (TSE) is important clinically. Unfortunately, 7 T TSE suffers from B 1 + ‐induced signal dropouts. Magnitude‐based parallel transmit (pTx) pulse design algorithms cannot enforce phase patterns complying with the Carr‐Purcell‐Meiboom‐Gill conditions (90° phase shift between excitation and refocusing). We introduce scalable spokes pTx pulses for 7 T TSE imaging. Theory We define scalable spokes pulses as having time‐symmetric RF waveforms, antisymmetric in‐plane gradients, and rephased subpulse slice‐selection gradients. They produce flip angles that are approximately proportional to the applied voltage with voltage‐independent phase patterns.
Methods
Scalable spokes pulses were designed for a phantom. Scaling behavior was characterized via Bloch simulations. Performance in terms of TSE echo homogeneity was assessed by extended phase graph simulations using in vivo field maps. Performance was validated for TSE acquisitions in a phantom and in vivo. Hippocampal TSE imaging was performed for four subjects comparing circularly polarized (CP), RF shimming, and scalable spokes pulses.
Results
Scalable spokes pTx pulses show similar scaling behavior to previously proposed 3D k T ‐point pulses. Scalable three‐spoke pulses decrease flip‐angle RMS error across subjects compared to CP mode pulses (11% vs. 23% for 120° pulses). TSE images with these pulses recover signals in cerebellum and temporal lobes.
Conclusion
Scalable spokes pTx pulses produce flip angles that vary approximately linearly with peak voltage while maintaining consistent spatial patterns of phase. Together with their spatial flip‐angle homogeneity, these pulses enable high‐fidelity 2D slice‐by‐slice TSE imaging at 7 T, albeit with reduced slice coverage with our choice of homogeneity target under the current vendor‐provided specific absorption rate constraints on 7 T MRI scanners.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Wolfson Brain Imaging Centre, University of Cambridge, Cambridge, United Kingdom.
ORCID-Profile: Minghao Zhang, Christopher T Rodgers
Förderung
- Cambridge Trust
- NIHR Cambridge Biomedical Research Centre
- Medical Research Council
Zitieren
APA
Zhang, M., & Rodgers, C. T. (2026). Scalable spokes pTx pulses for 2D turbo‐spin‐echo imaging at 7 T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70068
Vancouver
Zhang M, Rodgers CT. Scalable spokes pTx pulses for 2D turbo‐spin‐echo imaging at 7 T. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70068
BibTeX
@article{Zhang2026,
author = {Zhang, Minghao and Rodgers, Christopher T},
title = {Scalable spokes pTx pulses for 2D turbo‐spin‐echo imaging at 7 T},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70068}
}
EUVIMED