Enhancing computation speed and accuracy in deep image prior‐based parameter mapping
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30630 ↗At a glance
Journal article in Magnetic Resonance in Medicine, 2025. Written by Max Hellström and 3 co-authors. Institution: Department of Diagnostics and Intervention, Umeå University, Umeå, Sweden. Major MEDLINE topics: Magnetic Resonance Imaging, Image Processing, Computer-Assisted, Deep Learning. 53 references. The full text is freely available (open access, CC BY 4.0). Funded by: Cancerforskningsfonden i Norrland, Lions Cancerforskningsfond, Region Västerbotten (Bas ALF).
Abstract (original language)
Purpose
To make Deep Image Prior (DIP)‐based parameter mapping faster, more accurate, and suitable for clinical applications, with added support for multislice and 3D datasets.
Methods
DIP leverages the inherent structure of an untrained image generator to address various inverse imaging tasks, including denoising. In this study, we enhance DIP‐based denoising for parameter mapping with warm‐start across neighboring image slices and different patient subjects. This approach leverages spatial similarity to reduce computation time. Additionally, we introduce an early‐stopping criterion that selects the denoising level based on MRI signal noise. We further investigate uncertainty calibration through dropout probability tuning to address issues with miscalibrated uncertainty estimates from Monte Carlo dropout. Furthermore, we explore reducing computation time by tuning learning rates and network complexity.
Results
We show that reusing image generator weights with warm‐start significantly accelerates the denoising of large datasets, reducing computation time by 78% to 95% across various tasks. The early stopping approach proved effective, eliminating the need to manually select the number of optimization steps. Dropout probability tuning helps mitigate the issue of miscalibrated uncertainty, though further refinements are necessary, particularly to achieve better calibration on a per‐pixel level. Additionally, tuning learning rates and network complexity provided valuable insights into optimizing the model for different tasks.
Conclusion
The proposed developments enable DIP‐based parameter mapping to become faster, more accurate, and, consequently, more practical and scalable for clinical applications involving larger datasets.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Diagnostics and Intervention, Umeå University, Umeå, Sweden.
- Department of Computing Science, Umeå University, Umeå, Sweden.
ORCID profiles: Max Hellström, Polina Kurtser, Tommy Löfstedt, Anders Garpebring
Funding
- Cancerforskningsfonden i Norrland
- Lions Cancerforskningsfond
- Region Västerbotten (Bas ALF)
- The Swedish Research Council
Cite
APA
Hellström, M., Kurtser, P., Löfstedt, T., & Garpebring, A. (2025). Enhancing computation speed and accuracy in deep image prior‐based parameter mapping. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30630
Vancouver
Hellström M, Kurtser P, Löfstedt T, Garpebring A. Enhancing computation speed and accuracy in deep image prior‐based parameter mapping. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30630
BibTeX
@article{Hellstrm2025,
author = {Hellström, Max and Kurtser, Polina and Löfstedt, Tommy and Garpebring, Anders},
title = {Enhancing computation speed and accuracy in deep image prior‐based parameter mapping},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30630}
}
EUVIMED