EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Compressed sensing acceleration of radial 3‐D alternating Look‐Locker T1 mapping

Antti Aarnio iD, Olli Nykänen iD, Ville Kolehmainen iD, Mikko J Nissi iD

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30610 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Antti Aarnio und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Technical Physics, University of Eastern Finland, Kuopio, Finland. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Magnetic Resonance Imaging, Brain, Data Compression. Die Arbeit nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Finnish Cultural Foundation, North Savo regional fund, Research Council of Finland, Päivikki ja Sakari Sohlbergin Säätiö.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To determine how various compressed sensing (CS) models can accelerate alternating Look‐Locker mapping.

Methods

An alternating Look‐Locker acquisition was retrospectively accelerated by factors of 1–12. The data was reconstructed into 12 images with multiple CS models, which utilized combinations of spatial total variation, locally low‐rank regularization, and subspace constraints. Complex non‐linear least squares signal fitting was performed to obtain the maps. The accelerated maps were compared against the map of a full data reference reconstruction.

Results

A subspace‐constrained reconstruction model with spatial total variation and locally low‐rank regularization outperformed all other models as measured by map normalized root mean squared error, structural similarity index, and normalized mean absolute deviation. The subspace constraint benefited models utilizing spatial total variation but, conversely, did not benefit models utilizing only locally low‐rank regularization.

Conclusion

The radial 3‐D alternating Look‐Locker mapping acquisition was successfully accelerated by up to a factor of 12 with various CS models. The best‐performing model was a subspace‐constrained reconstruction, which utilized spatial total variation and locally low‐rank regularization.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalMagnetic Resonance ImagingBrainData CompressionImage Processing, Computer-AssistedHumansAlgorithmsPhantoms, ImagingRetrospective StudiesReproducibility of Results

Stichwörter der Autor:innen

T 1 $$ {T}_1 $$ relaxationacceleratedalternating Look‐Lockercompressed sensing

Autor:innen und Institutionen

  • Department of Technical Physics, University of Eastern Finland, Kuopio, Finland.

ORCID-Profile: Antti Aarnio, Olli Nykänen, Ville Kolehmainen, Mikko J Nissi

Förderung

  • Finnish Cultural Foundation, North Savo regional fund
  • Research Council of Finland
  • Päivikki ja Sakari Sohlbergin Säätiö
  • Suomen Kulttuurirahasto

Zitieren

APA

Aarnio, A., Nykänen, O., Kolehmainen, V., & Nissi, M. J. (2025). Compressed sensing acceleration of radial 3‐D alternating Look‐Locker T1 mapping. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30610

Vancouver

Aarnio A, Nykänen O, Kolehmainen V, Nissi MJ. Compressed sensing acceleration of radial 3‐D alternating Look‐Locker T1 mapping. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30610

BibTeX
@article{Aarnio2025,
  author = {Aarnio, Antti and Nykänen, Olli and Kolehmainen, Ville and Nissi, Mikko J},
  title = {Compressed sensing acceleration of radial 3‐D alternating Look‐Locker T1 mapping},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30610}
}
Kostenlos starten →