In vivo evaluation of population‐specific inversion pulses in parallel transmission
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30593 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Igor Tyshchenko und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering and Graeme Clark Institute, The University of Melbourne, Victoria, Australia. Hauptthemen laut MEDLINE: Brain, Magnetic Resonance Imaging, Image Processing, Computer-Assisted, Head. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Purpose
The aim of the study was to conduct in vivo evaluation of population‐specific pulses in the context of the MP2RAGE sequence for brain imaging at 7T.
Methods
Five clusters were identified in a cohort of 39 volunteers. One cluster centered around the average head shape and position, whereas four others were located toward the extremes of the population distribution. Additionally, the one‐size‐fits‐all solution was considered, using a standard universal pulse (UP) approach. Head shapes were characterized using lateral head breadth (HB), anterior–posterior head length (HL), and Y‐shift metrics. For each group, a 5kT‐points universal inversion pulse was computed and evaluated on four new test anatomies. A Python pipeline was integrated into the image reconstruction routine, using localizer scans to classify head shapes and positions. The pipeline selected one of five precomputed population‐specific pulses or defaulted to the generic UP without extending scan time.
Results
The pipeline accurately classified head shapes and selected suitable pulses, enhancing the contrast of MP2RAGE images. Population‐specific pulses helped mitigate some of the performance loss associated with using a one‐size‐fits‐all UP, bringing performance closer to that of fully tailored solutions. This approach was particularly beneficial for individuals with smaller head sizes. However, the performance was worse in larger, more challenging head shapes.
Conclusion
The novel head clustering and pulse selection pipeline facilitates the implementation of population‐specific pulses in clinical practice by allowing pulse selection tailored to each head shape and position without increasing scan time.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering and Graeme Clark Institute, The University of Melbourne, Victoria, Australia.
- Melbourne Brain Centre Imaging Unit, The University of Melbourne, Victoria, Australia.
- MR Research Collaborations, Siemens Healthcare Pty Ltd, Victoria, Australia.
- School of Computer Science, University of Birmingham, Birmingham, UK.
- The Florey Institute of Neuroscience and Mental Health, Victoria, Australia.
- Cardiovascular MR R&D, Siemens Healthcare GmbH, Calgary, Canada.
ORCID-Profile: Igor Tyshchenko, Simon Lévy, Joseph J Bartlett, Bahman Tahayori, Yasmin Blunck, Tudor V Sava, Kelvin Chow, Patrick Liebig, Rebecca Glarin, Leigh A Johnston
Zitieren
APA
Tyshchenko, I., Lévy, S., Bartlett, J. J., Tahayori, B., Blunck, Y., Sava, T. V., Chow, K., Liebig, P., Glarin, R., & Johnston, L. A. (2025). In vivo evaluation of population‐specific inversion pulses in parallel transmission. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30593
Vancouver
Tyshchenko I, Lévy S, Bartlett JJ, Tahayori B, Blunck Y, Sava TV, et al. In vivo evaluation of population‐specific inversion pulses in parallel transmission. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30593
BibTeX
@article{Tyshchenko2025,
author = {Tyshchenko, Igor and Lévy, Simon and Bartlett, Joseph J and Tahayori, Bahman and Blunck, Yasmin and Sava, Tudor V and Chow, Kelvin and Liebig, Patrick and Glarin, Rebecca and Johnston, Leigh A},
title = {In vivo evaluation of population‐specific inversion pulses in parallel transmission},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30593}
}
EUVIMED