EUVIMEDEUVIMED entdecken
Multizentrische StudieOpen Access

Establishing standardized healthy reference distributions and values for multisite 129 Xe gas exchange MRI / MR spectroscopy at 3 T across major scanner platforms

Suphachart Leewiwatwong iD, Aryil Bechtel iD, David Mummy, Shuo Zhang, Junlan Lu iD, Anna Costelle, Zackary I Cleveland iD, Matthew Willmering iD, Juan Parra-Robles, Sean Fain, Andrew D Hahn iD, Robert M Tighe und 1 weitere

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30586 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Suphachart Leewiwatwong und 12 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Engineering, Duke University, Durham, North Carolina, USA. Hauptthemen laut MEDLINE: Xenon Isotopes, Magnetic Resonance Imaging. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 74 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS, NIH HHS, NIH/NHLBI.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To establish standardized reference distributions and values for 1‐point Dixon 129 Xe gas exchange MRI/MR spectroscopy (MRS) in a multicenter healthy cohort of 18–30‐year‐olds scanned on three major 3T platforms. These distributions and values enable consistent, quantitative analysis and interpretation of images and spectra.

Methods

Healthy participants from three centers—Duke University (Siemens), Cincinnati Children's Hospital (Philips), and the University of Iowa (General Electric)—underwent pulmonary function testing and a standardized 129 Xe MRI/MRS protocol with dissolved‐phase excitation at 208 ppm from the gas resonance. Raw data were converted to the ISMRMRD format, centrally processed, and used to construct reference values and distributions for each gas‐exchange compartment. The combined reference values were compared to site‐specific values and, with suitable transformation, to a cohort evaluated with 218 ppm excitation.

Results

The reference distributions were consistent across sites and platforms for both imaging and spectroscopy. Combined imaging reference means were ventilation = 0.71 ± 0.14, membrane (M)/gas = 0.97 ± 0.27 × 10 −2 , red blood cell (RBC)/gas = 0.48 ± 0.20 × 10 −2 , and RBC:M = 0.49 ± 0.11. Spectroscopic chemical shifts were 197.6 ± 0.3 and 218.2 ± 0.5 ppm for membrane and RBC, with an RBC oscillation amplitude of 10.0 ± 2.5%. Estimated global T 2 * values were 0.99 ± 0.04 ms (membrane) and 1.04 ± 0.03 ms (RBC). Quantitative maps showed no significant differences using site‐specific versus combined distributions. Scaled 208‐ppm distributions agreed well with single‐site distributions acquired with 218‐ppm excitation.

Conclusions

These reference distributions provide a robust benchmark for 3T 129 Xe gas exchange MRI/MRS, ensuring rigor, reproducibility, and cross‐center comparability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Xenon IsotopesMagnetic Resonance ImagingHumansMaleAdultFemaleReference ValuesYoung AdultAdolescentMagnetic Resonance SpectroscopyHealthy VolunteersImage Processing, Computer-AssistedRespiratory Function Tests

Stichwörter der Autor:innen

129Xe gas exchange MRI/MRS3 Tcross‐platformmulticenterpulmonaryreference values

Substanzen

Xenon IsotopesXenon-129

Autor:innen und Institutionen

  • Biomedical Engineering, Duke University, Durham, North Carolina, USA.
  • Radiology, Duke University, Durham, North Carolina, USA.
  • Medical Physics Graduate Program, Duke University, Durham, North Carolina, USA.
  • Division of Pulmonary Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA.
  • Department of Pediatrics, University of Cincinnati, Cincinnati, Ohio, USA.
  • Department of Radiology, University of Iowa, Iowa City, Iowa, USA.

ORCID-Profile: Suphachart Leewiwatwong, Aryil Bechtel, Junlan Lu, Zackary I Cleveland, Matthew Willmering, Andrew D Hahn

Förderung

  • NHLBI NIH HHS
  • NIH HHS
  • NIH/NHLBI
  • National Heart, Lung, and Blood Institute

Zitieren

APA

Leewiwatwong, S., Bechtel, A., Mummy, D., Zhang, S., Lu, J., Costelle, A., Cleveland, Z. I., Willmering, M., Parra-Robles, J., Fain, S., Hahn, A. D., Tighe, R. M., & Driehuys, B. (2025). Establishing standardized healthy reference distributions and values for multisite 129 Xe gas exchange MRI / MR spectroscopy at 3 T across major scanner platforms. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30586

Vancouver

Leewiwatwong S, Bechtel A, Mummy D, Zhang S, Lu J, Costelle A, et al. Establishing standardized healthy reference distributions and values for multisite 129 Xe gas exchange MRI / MR spectroscopy at 3 T across major scanner platforms. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30586

BibTeX
@article{Leewiwatwong2025,
  author = {Leewiwatwong, Suphachart and Bechtel, Aryil and Mummy, David and Zhang, Shuo and Lu, Junlan and Costelle, Anna and Cleveland, Zackary I and Willmering, Matthew and Parra-Robles, Juan and Fain, Sean and Hahn, Andrew D and Tighe, Robert M and Driehuys, Bastiaan},
  title = {Establishing standardized healthy reference distributions and values for multisite 129 Xe gas exchange MRI / MR spectroscopy at 3 T across major scanner platforms},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30586}
}
Kostenlos starten →