EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Age, sex, and lung volume dependence of dissolved xenon‐129 MRI gas exchange metrics

Guilhem J Collier iD, Laurie J Smith, Laura C Saunders iD, Andrew J Swift, Helen Marshall, Neil J Stewart iD, Graham Norquay iD, Paul J C Hughes iD, A A Roger Thomspson iD, Jim M Wild

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.30133 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Guilhem J Collier und 9 weiteren Autor:innen. Beteiligte Einrichtung: POLARIS, Division of Clinical Medicine, School of Medicine & Population Health, University of Sheffield, Sheffield, UK. Hauptthemen laut MEDLINE: Xenon Isotopes, Magnetic Resonance Imaging, Lung. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Engineering and Physical Sciences Research Council, National Institute for Health and Care Research, Medical Research Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To characterize the dependence of Xe‐MRI gas transfer metrics upon age, sex, and lung volume in a group of healthy volunteers.

Methods

Sixty‐five subjects with no history of chronic lung disease were assessed with 129 Xe‐MRI using a four‐echo 3D radial spectroscopic imaging sequence and a dose of xenon titrated according to subject height that was inhaled from a lung volume of functional residual capacity (FRC). Imaging was repeated in 34 subjects at total lung capacity (TLC). Regional maps of the fractions of dissolved xenon in red blood cells (RBC), membrane (M), and airspace (Gas) were acquired at an isotropic resolution of 2 cm, from which global averages of the ratios RBC:M, RBC:Gas, and M:Gas were computed.

Results

Data from 26 males and 36 females with a median age of 43 y (range: 20–69 y) were of sufficient quality to analyze. Age ( p = 0.0006) and sex ( p < 0.0001) were significant predictors for RBC:M, and a linear regression showed higher values and steeper decline in males: RBC:M(Males) = −0.00362 × Age + 0.60 ( p = 0.01, R 2 = 0.25); RBC:M(Females) = −0.00170 × Age + 0.44 ( p = 0.02, R 2 = 0.15). Similarly, age and sex were significant predictors for RBC:Gas but not for M:Gas. RBC:M, M:Gas and RBC:Gas were significantly lower at TLC than at FRC (plus inhaled volume), with an average 9%, 30% and 35% decrease, respectively.

Conclusion

Expected age and sex dependence of pulmonary function concurs with 129 Xe RBC:M imaging results, demonstrating that these variables must be considered when reporting Xe‐MRI metrics. Xenon doses and breathing maneuvers should be controlled due to the strong dependence of Xe‐MRI metrics upon lung volume.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Xenon IsotopesMagnetic Resonance ImagingLungHumansMaleFemaleMiddle AgedAdultAgedYoung AdultPulmonary Gas ExchangeSex FactorsAge FactorsLung Volume MeasurementsErythrocytes

Stichwörter der Autor:innen

ageinghyperpolarized 129Xelunglung volumespectroscopic imaging

Substanzen

Xenon IsotopesXenon-129

Autor:innen und Institutionen

  • POLARIS, Division of Clinical Medicine, School of Medicine & Population Health, University of Sheffield, Sheffield, UK.
  • Insigneo Institute, University of Sheffield, Sheffield, UK.

ORCID-Profile: Guilhem J Collier, Laura C Saunders, Neil J Stewart, Graham Norquay, Paul J C Hughes, A A Roger Thomspson

Förderung

  • Engineering and Physical Sciences Research Council
  • National Institute for Health and Care Research
  • Medical Research Council

Zitieren

APA

Collier, G. J., Smith, L. J., Saunders, L. C., Swift, A. J., Marshall, H., Stewart, N. J., Norquay, G., Hughes, P. J. C., Thomspson, A. A. R., & Wild, J. M. (2024). Age, sex, and lung volume dependence of dissolved xenon‐129 MRI gas exchange metrics. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30133

Vancouver

Collier GJ, Smith LJ, Saunders LC, Swift AJ, Marshall H, Stewart NJ, et al. Age, sex, and lung volume dependence of dissolved xenon‐129 MRI gas exchange metrics. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30133

BibTeX
@article{Collier2024,
  author = {Collier, Guilhem J and Smith, Laurie J and Saunders, Laura C and Swift, Andrew J and Marshall, Helen and Stewart, Neil J and Norquay, Graham and Hughes, Paul J C and Thomspson, A A Roger and Wild, Jim M},
  title = {Age, sex, and lung volume dependence of dissolved xenon‐129 MRI gas exchange metrics},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30133}
}
Kostenlos starten →