EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

TE optimization for J‐difference editing of 2‐hydroxyglutarate at 3T

Kimberly L Chan iD, Rutul Hapani, Elizabeth A Maher, Toral R Patel, Anke Henning

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30561 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2025. Written by Kimberly L Chan and 4 co-authors. Institution: Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA. Major MEDLINE topics: Glutarates, Glioma, Brain Neoplasms, Magnetic Resonance Imaging. Cited 2 times so far (Crossref); 50 references. The full text is freely available (open access, CC BY 4.0). Funded by: Cancer Prevention and Research Institute of Texas (CPRIT).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

To investigate the TE dependence of the edited 2‐hydroxyglutarate (2HG) signal, its separation from co‐edited glutamate plus glutamine (Glx), and fit accuracy in the presence of nuisance signals using a MEGA‐PRESS sequence.

Methods

Simulations were performed at TEs 70–160 ms to assess the signal intensity and 2HG‐Glx overlap as a function of TE. The effect of the 2HG‐Glx spectral overlap on the fit accuracy of 2HG was evaluated on simulated 2HG‐edited spectra with in vivo parameter variations. Data were acquired at TEs of 70 and 90 ms in 13 glioma patients to estimate the TE‐dependence of the 2HG and Glx signal intensity and at a TE of 120 ms in eight glioma patients to estimate the in vivo 2HG, Glx, and water T2 relaxation times.

Results

A TE of 90 ms was found to produce a maximal 2HG integral, which was 23% larger than that at a TE of 70 ms in vivo without a significant increase in 2HG‐Glx overlap. Lipid and residual water were 26% and 16% lower, respectively, at a TE of 90 ms versus 70 ms. Fit‐quality numbers were 49% lower at a TE of 90 ms versus 70 ms, indicating enhanced fits at a TE of 90 ms. The in vivo T2 relaxation times of 2HG, Glx, and water were 264, 177, and 110 ms, respectively.

Conclusion

A TE of 90 ms was best with a maximal 2HG signal, minimal 2HG‐Glx overlap, and minimal residual water and lipid contamination.

Subjects

MeSH terms (MEDLINE)

GlutaratesGliomaBrain NeoplasmsMagnetic Resonance ImagingHumansMagnetic Resonance SpectroscopyMaleAdultFemaleMiddle AgedGlutamineAlgorithmsGlutamic AcidComputer Simulation

Author keywords

2HGJ‐difference editingMR spectroscopygliomatumor

Substances

Glutaratesalpha-hydroxyglutarateGlutamineGlutamic Acid

Authors and institutions

  • Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
  • Department of Psychiatry, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
  • Department of Biomedical Engineering, University of Texas Dallas, Dallas, Texas, USA.
  • Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
  • Department of Neurology, UT Southwestern Medical Center, Dallas, Texas, USA.
  • Department of Neurological Surgery, University of Texas Southwestern Medical Center, Dallas, Texas, USA.

ORCID profiles: Kimberly L Chan

Funding

  • Cancer Prevention and Research Institute of Texas (CPRIT)

Cite

APA

Chan, K. L., Hapani, R., Maher, E. A., Patel, T. R., & Henning, A. (2025). TE optimization for J‐difference editing of 2‐hydroxyglutarate at 3T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30561

Vancouver

Chan KL, Hapani R, Maher EA, Patel TR, Henning A. TE optimization for J‐difference editing of 2‐hydroxyglutarate at 3T. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30561

BibTeX
@article{Chan2025,
  author = {Chan, Kimberly L and Hapani, Rutul and Maher, Elizabeth A and Patel, Toral R and Henning, Anke},
  title = {TE optimization for J‐difference editing of 2‐hydroxyglutarate at 3T},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30561}
}
Start for free →