TE optimization for J‐difference editing of 2‐hydroxyglutarate at 3T
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30561 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Kimberly L Chan und 4 weiteren Autor:innen. Beteiligte Einrichtung: Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA. Hauptthemen laut MEDLINE: Glutarates, Glioma, Brain Neoplasms, Magnetic Resonance Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Cancer Prevention and Research Institute of Texas (CPRIT).
Abstract (Originalsprache)
Purpose
To investigate the TE dependence of the edited 2‐hydroxyglutarate (2HG) signal, its separation from co‐edited glutamate plus glutamine (Glx), and fit accuracy in the presence of nuisance signals using a MEGA‐PRESS sequence.
Methods
Simulations were performed at TEs 70–160 ms to assess the signal intensity and 2HG‐Glx overlap as a function of TE. The effect of the 2HG‐Glx spectral overlap on the fit accuracy of 2HG was evaluated on simulated 2HG‐edited spectra with in vivo parameter variations. Data were acquired at TEs of 70 and 90 ms in 13 glioma patients to estimate the TE‐dependence of the 2HG and Glx signal intensity and at a TE of 120 ms in eight glioma patients to estimate the in vivo 2HG, Glx, and water T2 relaxation times.
Results
A TE of 90 ms was found to produce a maximal 2HG integral, which was 23% larger than that at a TE of 70 ms in vivo without a significant increase in 2HG‐Glx overlap. Lipid and residual water were 26% and 16% lower, respectively, at a TE of 90 ms versus 70 ms. Fit‐quality numbers were 49% lower at a TE of 90 ms versus 70 ms, indicating enhanced fits at a TE of 90 ms. The in vivo T2 relaxation times of 2HG, Glx, and water were 264, 177, and 110 ms, respectively.
Conclusion
A TE of 90 ms was best with a maximal 2HG signal, minimal 2HG‐Glx overlap, and minimal residual water and lipid contamination.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
- Department of Psychiatry, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
- Department of Biomedical Engineering, University of Texas Dallas, Dallas, Texas, USA.
- Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
- Department of Neurology, UT Southwestern Medical Center, Dallas, Texas, USA.
- Department of Neurological Surgery, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
ORCID-Profile: Kimberly L Chan
Förderung
- Cancer Prevention and Research Institute of Texas (CPRIT)
Zitieren
APA
Chan, K. L., Hapani, R., Maher, E. A., Patel, T. R., & Henning, A. (2025). TE optimization for J‐difference editing of 2‐hydroxyglutarate at 3T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30561
Vancouver
Chan KL, Hapani R, Maher EA, Patel TR, Henning A. TE optimization for J‐difference editing of 2‐hydroxyglutarate at 3T. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30561
BibTeX
@article{Chan2025,
author = {Chan, Kimberly L and Hapani, Rutul and Maher, Elizabeth A and Patel, Toral R and Henning, Anke},
title = {TE optimization for J‐difference editing of 2‐hydroxyglutarate at 3T},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30561}
}
EUVIMED