Improving quantitative BOLD –based measures of oxygen extraction fraction using hyperoxia BOLD –derived measures of blood volume
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30559 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Alan J Stone und 1 weiteren Autor:innen. Beteiligte Einrichtung: Wellcome Center for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Oxygen, Hyperoxia, Brain. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Engineering and Physical Sciences Research Council.
Abstract (Originalsprache)
Purpose
Streamlined quantitative BOLD (sqBOLD) is a refinement of the quantitative BOLD (qBOLD) technique capable of producing noninvasive and quantitative maps of oxygen extraction fraction (OEF) in a clinically feasible scan time. However, sqBOLD measurements of OEF have been reported as being systematically lower than expected in healthy brain. Because the qBOLD framework infers OEF from the ratio of the reversible transverse relaxation rate () and deoxygenated blood volume (DBV), this underestimation has been attributed the overestimation of DBV. Therefore, this study proposes the use of an independent measure of DBV using hyperoxia BOLD and investigates whether this results in improved estimates of OEF.
Methods
Monte Carlo simulations were used to simulate the qBOLD and hyperoxia‐BOLD signals and to compare the systematic and noise‐related errors of sqBOLD and the new hyperoxia‐qBOLD (hqBOLD) technique. Experimentally, sqBOLD and hqBOLD measurements were performed and compared with TRUST (T 2 relaxation under spin tagging)–based oximetry in the sagittal sinus.
Results
Simulations showed a large improvement in the uncertainty of DBV measurements, leading to a much improved dynamic range for OEF measurements with hqBOLD. In a group of 10 healthy volunteers, hqBOLD produced measurements of OEF in cortical gray matter (OEF hqBOLD = 38.1 ± 10.1%) that were not significantly different from TRUST oximetry measures (OEF TRUST = 40.4 ± 7.7%), whereas sqBOLD‐derived measures (OEF sqBOLD = 16.1 ± 3.1%) were found to be significantly different.
Conclusion
The simulations and experiments in this study demonstrate that an independent measure of DBV provides improved estimates of OEF.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Wellcome Center for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.
- Department of Medical Physics and Clinical Engineering, Beaumont Hospital, Dublin, Ireland.
- National Neuroscience Center, Beaumont Hospital, Dublin, Ireland.
- Center for Physics and Health in Medicine, School of Physics, University College Dublin, Dublin, Ireland.
- School of Life Sciences, University of Nottingham, Nottingham, UK.
ORCID-Profile: Nicholas P Blockley
Förderung
- Engineering and Physical Sciences Research Council
Zitieren
APA
Stone, A. J., & Blockley, N. P. (2025). Improving quantitative BOLD –based measures of oxygen extraction fraction using hyperoxia BOLD –derived measures of blood volume. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30559
Vancouver
Stone AJ, Blockley NP. Improving quantitative BOLD –based measures of oxygen extraction fraction using hyperoxia BOLD –derived measures of blood volume. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30559
BibTeX
@article{Stone2025,
author = {Stone, Alan J and Blockley, Nicholas P},
title = {Improving quantitative BOLD –based measures of oxygen extraction fraction using hyperoxia BOLD –derived measures of blood volume},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30559}
}
EUVIMED