EUVIMEDEUVIMED entdecken
Open Access

MULti‐TImepoint VElocity‐selective Reconciled with Spatially‐sElective (MULTIVERSE) ASL: Improving robustness to both shortened and prolonged arterial transit time

Feng Xu iD, Dan Zhu iD, Dapeng Liu iD, Anja Soldan, Marilyn Albert, Martin A Lindquist, Doris D M Lin, Qin Qin iD

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30540 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Feng Xu und 7 weiteren Autor:innen. Beteiligte Einrichtung: The Russell H. Morgan Department of Radiology and Radiological Science, School of Medicine, Johns Hopkins University, Baltimore, Maryland, USA. Hauptthemen laut MEDLINE: Cerebrovascular Circulation, Brain, Image Processing, Computer-Assisted, Magnetic Resonance Imaging. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, NIA NIH HHS, National Heart and Lung Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To improve the quantification of existing multi‐timepoint arterial spin labeling (ASL) methods in estimating cerebral blood flow (CBF) and arterial transit time (ATT) for a wider range of ATTs.

Methods

MULti‐TImepoint VElocity‐selective Reconciled with Spatially‐sElective (MULTIVERSE) ASL utilizes multi‐delay pseudo‐continuous (PC) ASL and velocity‐selective (VS) ASL with spatially defined bolus, and joint fitting to estimate CBF and ATT. Numerical simulations were performed to evaluate the accuracy and precision of single‐delay and multi‐delay PCASL and VSASL, as well as the proposed MULTIVERSE ASL, in quantifying CBF and ATT across an extended range of ATTs. The CBF and ATT estimates between multi‐delay PCASL, VSASL, and MULTIVERSE ASL were compared across healthy volunteers.

Results

Numerical simulations showed that the utility of MULTIVERSE ASL improved the accuracy and precision over an extended ATT range of up to 4000 ms. In vivo scans from healthy subjects demonstrated that MULTIVERSE ASL led to reduced uncertainty in CBF and ATT quantification compared to multi–post‐labeling delay PCASL while maintaining comparable repeatability.

Conclusion

This novel and straightforward approach improves the accuracy and precision of the fitted CBF and ATT over an extended range of ATT, which is not possible with existing ASL methods. Brain scans from healthy subjects demonstrated the feasibility and reliability of the technique, highlighting the clinical potential of ASL‐based perfusion mapping in various altered physiological and pathological conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cerebrovascular CirculationBrainImage Processing, Computer-AssistedMagnetic Resonance ImagingMagnetic Resonance AngiographyHumansSpin LabelsAdultMaleBlood Flow VelocityAlgorithmsComputer SimulationFemaleReproducibility of ResultsHealthy VolunteersYoung Adult

Stichwörter der Autor:innen

MULTIVERSE ASLarterial spin labeling (ASL)arterial transit time (ATT)bolus arrival time (BAT)bolus durationcerebral blood flowpseudo‐continuous ASL (PCASL)velocity‐selective ASL (VSASL)

Substanzen

Spin Labels

Autor:innen und Institutionen

  • The Russell H. Morgan Department of Radiology and Radiological Science, School of Medicine, Johns Hopkins University, Baltimore, Maryland, USA.
  • F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA.
  • Department of Neurology, School of Medicine, Johns Hopkins University, Baltimore, Maryland, USA.
  • Department of Biostatistics, Bloomberg School of Public Health, Johns Hopkins University, Baltimore, Maryland, USA.

ORCID-Profile: Feng Xu, Dan Zhu, Dapeng Liu, Qin Qin

Förderung

  • NIBIB NIH HHS
  • NIA NIH HHS
  • National Heart and Lung Institute
  • NHLBI NIH HHS
  • Division of Cancer Prevention, National Cancer Institute
  • NINDS NIH HHS
  • NCI NIH HHS
  • National Institute of Neurological Disorders and Stroke

Zitieren

APA

Xu, F., Zhu, D., Liu, D., Soldan, A., Albert, M., Lindquist, M. A., Lin, D. D. M., & Qin, Q. (2025). MULti‐TImepoint VElocity‐selective Reconciled with Spatially‐sElective (MULTIVERSE) ASL: Improving robustness to both shortened and prolonged arterial transit time. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30540

Vancouver

Xu F, Zhu D, Liu D, Soldan A, Albert M, Lindquist MA, et al. MULti‐TImepoint VElocity‐selective Reconciled with Spatially‐sElective (MULTIVERSE) ASL: Improving robustness to both shortened and prolonged arterial transit time. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30540

BibTeX
@article{Xu2025,
  author = {Xu, Feng and Zhu, Dan and Liu, Dapeng and Soldan, Anja and Albert, Marilyn and Lindquist, Martin A and Lin, Doris D M and Qin, Qin},
  title = {MULti‐TImepoint VElocity‐selective Reconciled with Spatially‐sElective (MULTIVERSE) ASL: Improving robustness to both shortened and prolonged arterial transit time},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30540}
}
Kostenlos starten →