Kurz gefasst

Vergleichsstudie in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Patrik Jan Gallinnis und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düss…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Kidney, Sodium, Image Processing, Computer-Assisted. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Jürgen Manchot Stiftung, PJG and RK, Jürgen Manchot Stiftung.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

23 Na MRI is a functional imaging technique that facilitates measurements of the renal corticomedullary sodium gradient (CMSG). The CMSG can be determined by a region of interest (ROI) in the renal parenchyma along the corticomedullary axis (Line method) or by dividing the renal parenchyma into concentric layers, using the twelve‐layer concentric objects (TLCO) method. The aim of this study was to investigate the differences, strengths, and weaknesses in determining the CMSG using these methods.

Methods

Ten healthy volunteers were examined on a 3 T MRI‐system. 23 Na images were acquired using a double‐tuned 23 Na/ 1 H surface coil and a golden angle (GA) density‐adapted 3D radial (DA‐3D‐RAD) sequence. The CMSG was determined with the Line and TLCO methods. Intra‐ and inter‐reader analyses were performed by two radiologists.

Results

The evaluated CMSG by the two methods does not differ statistically significantly. Compared to the Line method, the TLCO method provides improved results in terms of reliability, precision, reproducibility, and concordance in intra‐ and inter‐reader analyses. A CMSG of (6.7 ± 2.6) mM/mm was determined using the TLCO method in the segmentation process with the lowest standard deviation.

Conclusion

The TLCO method shows superior performance in determining the CMSG compared to the Line method. Accordingly, the use of the TLCO method is recommended for future renal CMSG studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingKidneySodiumImage Processing, Computer-AssistedHumansAdultReproducibility of ResultsMaleFemaleImaging, Three-DimensionalHealthy VolunteersSodium IsotopesAlgorithmsImage Interpretation, Computer-AssistedYoung Adult

Stichwörter der Autor:innen

corticomedullary 23Na gradientkidney sodium MRIsodium MRI23Na MR imagingtwelve‐layer concentric objects (TLCO) method

Substanzen

SodiumSodium Isotopes

Autor:innen und Institutionen

  • Department of Diagnostic and Interventional Radiology, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany.
  • Diagnostic and Interventional Radiology, Department of Radiology, University Hospital of Tuebingen, Tübingen, Germany.
  • Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Davison of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.
  • Core Facility for Magnetic Resonance Imaging, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany.

ORCID-Profile: Alexandra Ljimani, Armin M Nagel, Eric Bechler, Hans-Jörg Wittsack

Förderung

  • Jürgen Manchot Stiftung, PJG and RK
  • Jürgen Manchot Stiftung

Zitieren

APA

Gallinnis, P. J., Möller, R., Ljimani, A., Cabuk, Y., Scheuer, M., Böttger, C., Liang, C., Nagel, A. M., Bechler, E., Wittsack, H. J., Müller-Lutz, A., & Kamp, B. (2025). Comparison of twelve‐layer concentric object ( TLCO ) and Line segmentations methods to determine the renal corticomedullary sodium gradient ( CMSG ) with a 3 T MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30525

Vancouver

Gallinnis PJ, Möller R, Ljimani A, Cabuk Y, Scheuer M, Böttger C, et al. Comparison of twelve‐layer concentric object ( TLCO ) and Line segmentations methods to determine the renal corticomedullary sodium gradient ( CMSG ) with a 3 T MRI. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30525

BibTeX
@article{Gallinnis2025,
  author = {Gallinnis, Patrik Jan and Möller, Rika and Ljimani, Alexandra and Cabuk, Yusuf and Scheuer, Marie and Böttger, Charlotte and Liang, Cecilia and Nagel, Armin M and Bechler, Eric and Wittsack, Hans-Jörg and Müller-Lutz, Anja and Kamp, Benedikt},
  title = {Comparison of twelve‐layer concentric object ( TLCO ) and Line segmentations methods to determine the renal corticomedullary sodium gradient ( CMSG ) with a 3 T MRI},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30525}
}
Kostenlos starten →