A data‐driven approach for improved quantification of in vivo metabolic conversion rates of hyperpolarized [1‐ 13 C ]pyruvate
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30445 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Yaewon Kim und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA. Hauptthemen laut MEDLINE: Pyruvic Acid, Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIBIB NIH HHS, NCI NIH HHS, NIH HHS.
Abstract (Originalsprache)
Purpose
Accurate quantification of metabolism in hyperpolarized (HP) 13 C MRI is essential for clinical applications. However, kinetic model parameters are often confounded by uncertainties in radiofrequency flip angles and other model parameters.
Methods
A data‐driven kinetic fitting approach for HP 13 C‐pyruvate MRI was proposed that compensates for uncertainties in the B 1 + field. We hypothesized that introducing a scaling factor to the flip angle to minimize fit residuals would allow more accurate determination of the pyruvate‐to‐lactate conversion rate ( k PL ). Numerical simulations were performed under different conditions (flip angle, k PL , and T 1 relaxation), with further testing using HP 13 C‐pyruvate MRI of rat liver and kidneys.
Results
Simulations showed that the proposed method reduced k PL error from 60% to 1% when the prescribed and actual flip angles differed by 60%. The method also showed robustness to T 1 uncertainties, achieving median k PL errors within ±3% even when the assumed T 1 was incorrect by up to a factor of 2. In rat studies, better‐quality fitting for lactate signals (a 1.4‐fold decrease in root mean square error [RMSE] for lactate fit) and tighter k PL distributions (an average of 3.1‐fold decrease in k PL standard deviation) were achieved using the proposed method compared with when no correction was applied.
Conclusion
The proposed data‐driven kinetic fitting approach provided a method to accurately quantify HP 13 C‐pyruvate metabolism in the presence of B 1 + inhomogeneity. This model may also be used to correct for other error sources, such as T 1 relaxation and flow, and may prove to be clinically valuable in improving tumor staging or assessing treatment response.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA.
- Department of Neurological Surgery, University of California, San Francisco, California, USA.
- Mallinckrodt Institute of Radiology, Washington University, St. Louis, Missouri, USA.
ORCID-Profile: Yaewon Kim, Tanner M Nickles, Jeremy W Gordon, Peder E Z Larson, Cornelius von Morze, Michael A Ohliger
Förderung
- NIBIB NIH HHS
- NCI NIH HHS
- NIH HHS
- NIDDK NIH HHS
- NHLBI NIH HHS
- National Institutes of Health
Zitieren
APA
Kim, Y., Nickles, T. M., Lee, P. M., Bok, R. A., Gordon, J. W., Larson, P. E. Z., Vigneron, D. B., von Morze, C., & Ohliger, M. A. (2025). A data‐driven approach for improved quantification of in vivo metabolic conversion rates of hyperpolarized [1‐ 13 C ]pyruvate. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30445
Vancouver
Kim Y, Nickles TM, Lee PM, Bok RA, Gordon JW, Larson PEZ, et al. A data‐driven approach for improved quantification of in vivo metabolic conversion rates of hyperpolarized [1‐ 13 C ]pyruvate. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30445
BibTeX
@article{Kim2025,
author = {Kim, Yaewon and Nickles, Tanner M and Lee, Philip M and Bok, Robert A and Gordon, Jeremy W and Larson, Peder E Z and Vigneron, Daniel B and von Morze, Cornelius and Ohliger, Michael A},
title = {A data‐driven approach for improved quantification of in vivo metabolic conversion rates of hyperpolarized [1‐ 13 C ]pyruvate},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30445}
}
EUVIMED