EUVIMEDOpdag EUVIMED
Crossref

Isotropic sampling of tensor‐encoded diffusion MRI

Sune Nørhøj Jespersen iD

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30404 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2025. Written by Sune Nørhøj Jespersen. Institution: Department of Clinical Medicine, Aarhus University, Aarhus, Denmark. Major MEDLINE topics: Algorithms, Image Enhancement, Diffusion Magnetic Resonance Imaging, Diffusion Tensor Imaging. Cited 1 times so far (Crossref); 36 references. Funded by: Lundbeck Foundation.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

The purpose of this study is to develop a method for selecting uniform wave vectors for double diffusion encoding (DDE) to improve the accuracy and reliability of diffusion measurements.

Methods

The method relies on identifying orthogonal wave vectors with rotations, and representing these rotations as points on a three‐dimensional sphere in four dimensions using quaternions. This enables an electrostatic repulsion algorithm to achieve a uniform distribution of these points. The optimal points are then converted back into orthogonal wave vectors (or rotations).

Results

The method was validated by comparing the distribution of directions to those generated by uniform sampling and by evaluating the error in the powder‐averaged signal for various models. Our results demonstrate that the electrostatic repulsion approach effectively achieves a uniform distribution of wave vectors.

Conclusion

The proposed method provides a systematic way to generate uniform diffusion directions suitable, for example, for DDE, enhancing the precision of diffusion measurements and reducing potential bias in experimental results. The method is also capable of generating uniform sets of B‐tensors, and is thus applicable for general free waveform encoding.

Subjects

MeSH terms (MEDLINE)

AlgorithmsImage EnhancementDiffusion Magnetic Resonance ImagingDiffusion Tensor ImagingImage Interpretation, Computer-AssistedSignal Processing, Computer-AssistedBrainImaging, Three-DimensionalReproducibility of ResultsHumansSensitivity and SpecificitySample SizePhantoms, ImagingAnisotropy

Author keywords

diffusion MRIdouble diffusion encodingelectrostatic repulsionfree waveform encodingquaternionswave vectors

Authors and institutions

  • Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.
  • Department of Physics and Astronomy, Aarhus University, Aarhus, Denmark.

ORCID profiles: Sune Nørhøj Jespersen

Funding

  • Lundbeck Foundation

Cite

APA

Jespersen, S. N. (2025). Isotropic sampling of tensor‐encoded diffusion MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30404

Vancouver

Jespersen SN. Isotropic sampling of tensor‐encoded diffusion MRI. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30404

BibTeX
@article{Jespersen2025,
  author = {Jespersen, Sune Nørhøj},
  title = {Isotropic sampling of tensor‐encoded diffusion MRI},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30404}
}
Start for free →