Toward quantitative CEST imaging of glutamate in the mouse brain using a multi‐pool exchange model calibrated by 1 H ‐ MRS

Cécile Maguin iD, Eloïse Mougel iD, Julien Valette iD, Julien Flament iD

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30353 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2025. Written by Cécile Maguin and 3 co-authors. Institution: Molecular Imaging Research Center, Laboratoire des Maladies Neurodégénératives, Université Paris-Saclay, Commissariat à l'Energie Atomique et aux Ene…. Major MEDLINE topics: Glutamic Acid, Brain, Magnetic Resonance Imaging. Cited 5 times so far (Crossref); 60 references. The full text is freely available (open access, CC BY 4.0). Funded by: NeurATRIS: A Translational Research Infrastructure for Biotherapies in Neurosciences.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

To develop a CEST quantification model to map glutamate concentration in the mouse brain at 11.7 T, overcoming the limitations of conventional glutamate‐weighted CEST (gluCEST) contrast (magnetization transfer ratio with asymmetric analysis).

Methods

1 H‐MRS was used as a gold standard for glutamate quantification to calibrate a CEST‐based quantitative pipeline. Joint localized measurements of Z‐spectra at B 1 = 5 μT and quantitative 1 H‐MRS were carried out in two voxels of interest in the mouse brain. A six‐pool Bloch‐McConnell model was found appropriate to fit experimental data. Glutamate exchange rate was estimated in both regions with this dedicated multi‐pool fitting model and using glutamate concentration determined by 1 H‐MRS.

Results

Glutamate exchange rate was estimated to be ˜1300 Hz in the mouse brain. Using this calibrated value, maps of glutamate concentration in the mouse brain were obtained by pixel‐by‐pixel fitting of Z‐spectra at B 1 = 5 μT. A complementary study of simulations, however, showed that the quantitative model has high sensitivity to noise, and therefore, requires high‐SNR acquisitions. Interestingly, fitted [Glu] seemed to be overestimated compared to 1 H‐MRS measurements, although it was estimated with simulations that the model has no intrinsic fitting bias with our experimental level of noise. The hypothesis of an unknown proton‐exchanging pool contributing to gluCEST signal is discussed.

Conclusion

High‐resolution mapping of glutamate in the brain was made possible using the proposed calibrated quantification model of gluCEST data. Further studying of the in vivo molecular contributions to gluCEST signal could improve modeling.

Subjects

MeSH terms (MEDLINE)

Glutamic AcidBrainMagnetic Resonance ImagingAnimalsMiceCalibrationImage Processing, Computer-AssistedProton Magnetic Resonance SpectroscopyMice, Inbred C57BLAlgorithmsComputer SimulationSignal-To-Noise RatioPhantoms, ImagingMale

Author keywords

1H‐MRSBloch‐McConnell fittingCESTglutamatequantificationquantitative CEST

Substances

Glutamic Acid

Authors and institutions

  • Molecular Imaging Research Center, Laboratoire des Maladies Neurodégénératives, Université Paris-Saclay, Commissariat à l'Energie Atomique et aux Energies Alternatives, Centre National de la Recherche Scientifique, Font…

ORCID profiles: Cécile Maguin, Eloïse Mougel, Julien Valette, Julien Flament

Funding

  • NeurATRIS: A Translational Research Infrastructure for Biotherapies in Neurosciences

Cite

APA

Maguin, C., Mougel, E., Valette, J., & Flament, J. (2025). Toward quantitative CEST imaging of glutamate in the mouse brain using a multi‐pool exchange model calibrated by 1 H ‐ MRS. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30353

Vancouver

Maguin C, Mougel E, Valette J, Flament J. Toward quantitative CEST imaging of glutamate in the mouse brain using a multi‐pool exchange model calibrated by 1 H ‐ MRS. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30353

BibTeX
@article{Maguin2025,
  author = {Maguin, Cécile and Mougel, Eloïse and Valette, Julien and Flament, Julien},
  title = {Toward quantitative CEST imaging of glutamate in the mouse brain using a multi‐pool exchange model calibrated by 1 H ‐ MRS},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30353}
}
Start for free →