Toward quantitative CEST imaging of glutamate in the mouse brain using a multi‐pool exchange model calibrated by 1 H ‐ MRS
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30353 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Cécile Maguin und 3 weiteren Autor:innen. Beteiligte Einrichtung: Molecular Imaging Research Center, Laboratoire des Maladies Neurodégénératives, Université Paris-Saclay, Commissariat à l'Energie Atomique et aux Ene…. Hauptthemen laut MEDLINE: Glutamic Acid, Brain, Magnetic Resonance Imaging. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NeurATRIS: A Translational Research Infrastructure for Biotherapies in Neurosciences.
Abstract (Originalsprache)
Purpose
To develop a CEST quantification model to map glutamate concentration in the mouse brain at 11.7 T, overcoming the limitations of conventional glutamate‐weighted CEST (gluCEST) contrast (magnetization transfer ratio with asymmetric analysis).
Methods
1 H‐MRS was used as a gold standard for glutamate quantification to calibrate a CEST‐based quantitative pipeline. Joint localized measurements of Z‐spectra at B 1 = 5 μT and quantitative 1 H‐MRS were carried out in two voxels of interest in the mouse brain. A six‐pool Bloch‐McConnell model was found appropriate to fit experimental data. Glutamate exchange rate was estimated in both regions with this dedicated multi‐pool fitting model and using glutamate concentration determined by 1 H‐MRS.
Results
Glutamate exchange rate was estimated to be ˜1300 Hz in the mouse brain. Using this calibrated value, maps of glutamate concentration in the mouse brain were obtained by pixel‐by‐pixel fitting of Z‐spectra at B 1 = 5 μT. A complementary study of simulations, however, showed that the quantitative model has high sensitivity to noise, and therefore, requires high‐SNR acquisitions. Interestingly, fitted [Glu] seemed to be overestimated compared to 1 H‐MRS measurements, although it was estimated with simulations that the model has no intrinsic fitting bias with our experimental level of noise. The hypothesis of an unknown proton‐exchanging pool contributing to gluCEST signal is discussed.
Conclusion
High‐resolution mapping of glutamate in the brain was made possible using the proposed calibrated quantification model of gluCEST data. Further studying of the in vivo molecular contributions to gluCEST signal could improve modeling.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Molecular Imaging Research Center, Laboratoire des Maladies Neurodégénératives, Université Paris-Saclay, Commissariat à l'Energie Atomique et aux Energies Alternatives, Centre National de la Recherche Scientifique, Font…
ORCID-Profile: Cécile Maguin, Eloïse Mougel, Julien Valette, Julien Flament
Förderung
- NeurATRIS: A Translational Research Infrastructure for Biotherapies in Neurosciences
Zitieren
APA
Maguin, C., Mougel, E., Valette, J., & Flament, J. (2025). Toward quantitative CEST imaging of glutamate in the mouse brain using a multi‐pool exchange model calibrated by 1 H ‐ MRS. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30353
Vancouver
Maguin C, Mougel E, Valette J, Flament J. Toward quantitative CEST imaging of glutamate in the mouse brain using a multi‐pool exchange model calibrated by 1 H ‐ MRS. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30353
BibTeX
@article{Maguin2025,
author = {Maguin, Cécile and Mougel, Eloïse and Valette, Julien and Flament, Julien},
title = {Toward quantitative CEST imaging of glutamate in the mouse brain using a multi‐pool exchange model calibrated by 1 H ‐ MRS},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30353}
}
EUVIMED