Compressed sensing reconstruction for high‐ SNR , rapid dissolved 129 Xe gas exchange MRI
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30312 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Jemima H Pilgrim-Morris und 5 weiteren Autor:innen. Beteiligte Einrichtung: POLARIS, Section of Medical Imaging and Technologies, Division of Clinical Medicine, School of Medicine and Population Health, University of Sheffiel…. Hauptthemen laut MEDLINE: Xenon Isotopes, Magnetic Resonance Imaging, Signal-To-Noise Ratio, COVID-19. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Engineering and Physical Sciences Research Council, Medical Research Council.
Abstract (Originalsprache)
Purpose
Three‐dimensional hyperpolarized 129 Xe gas exchange imaging suffers from low SNR and long breath‐holds, which could be improved using compressed sensing (CS). The purpose of this work was to assess whether gas exchange ratio maps are quantitatively preserved in CS‐accelerated dissolved‐phase 129 Xe imaging and to investigate the feasibility of CS‐dissolved 129 Xe imaging with reduced‐cost natural abundance (NA) xenon.
Methods
129 Xe gas exchange imaging was performed at 1.5 T with a multi‐echo spectroscopic imaging sequence. A CS reconstruction with an acceleration factor of 2 was compared retrospectively with conventional gridding reconstruction in a cohort of 16 healthy volunteers, 5 chronic obstructive pulmonary disease patients, and 23 patients who were hospitalized following COVID‐19 infection. Metrics of comparison included normalized mean absolute error, mean gas exchange ratio, and red blood cell (RBC) image SNR. Dissolved 129 Xe CS imaging with NA xenon was assessed in 4 healthy volunteers.
Results
CS reconstruction enabled acquisition time to be halved, and it reduced background noise. Median RBC SNR increased from 6 (2–18) to 11 (2–100) with CS, and there was strong agreement between CS and gridding mean ratio map values (R 2 = 0.99). Image fidelity was maintained for gridding RBC SNR > 5, but below this, normalized mean absolute error increased nonlinearly with decreasing SNR. CS increased the mean SNR of NA 129 Xe images 3‐fold.
Conclusion
CS reconstruction of dissolved 129 Xe imaging improved image quality with decreased scan time, while preserving key gas exchange metrics. This will benefit patients with breathlessness and/or low gas transfer and shows promise for NA‐dissolved 129 Xe imaging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- POLARIS, Section of Medical Imaging and Technologies, Division of Clinical Medicine, School of Medicine and Population Health, University of Sheffield, Sheffield, UK.
- Insigneo Institute, University of Sheffield, Sheffield, UK.
ORCID-Profile: Jemima H Pilgrim-Morris, Guilhem J Collier, Graham Norquay, Neil J Stewart
Förderung
- Engineering and Physical Sciences Research Council
- Medical Research Council
Zitieren
APA
Pilgrim-Morris, J. H., Collier, G. J., Munro, R. S., Norquay, G., Stewart, N. J., & Wild, J. M. (2025). Compressed sensing reconstruction for high‐ SNR , rapid dissolved 129 Xe gas exchange MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30312
Vancouver
Pilgrim-Morris JH, Collier GJ, Munro RS, Norquay G, Stewart NJ, Wild JM. Compressed sensing reconstruction for high‐ SNR , rapid dissolved 129 Xe gas exchange MRI. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30312
BibTeX
@article{PilgrimMorris2025,
author = {Pilgrim-Morris, Jemima H and Collier, Guilhem J and Munro, Ryan S and Norquay, Graham and Stewart, Neil J and Wild, Jim M},
title = {Compressed sensing reconstruction for high‐ SNR , rapid dissolved 129 Xe gas exchange MRI},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30312}
}
EUVIMED