3D MR fingerprinting for dynamic contrast‐enhanced imaging of whole mouse brain
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30253 ↗At a glance
Journal article in Magnetic Resonance in Medicine, 2025. Written by Yuran Zhu and 11 co-authors. Institution: Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA. Major MEDLINE topics: Contrast Media, Imaging, Three-Dimensional, Magnetic Resonance Imaging, Brain. Cited 3 times so far (Crossref); 56 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: NIGMS NIH HHS, American Heart Association, NCATS NIH HHS.
Abstract (original language)
Purpose
Quantitative MRI enables direct quantification of contrast agent concentrations in contrast‐enhanced scans. However, the lengthy scan times required by conventional methods are inadequate for tracking contrast agent transport dynamically in mouse brain. We developed a 3D MR fingerprinting (MRF) method for simultaneous T 1 and T 2 mapping across the whole mouse brain with 4.3‐min temporal resolution.
Method
We designed a 3D MRF sequence with variable acquisition segment lengths and magnetization preparations on a 9.4T preclinical MRI scanner. Model‐based reconstruction approaches were employed to improve the accuracy and speed of MRF acquisition. The method's accuracy for T 1 and T 2 measurements was validated in vitro, while its repeatability of T 1 and T 2 measurements was evaluated in vivo ( n = 3). The utility of the 3D MRF sequence for dynamic tracking of intracisternally infused gadolinium‐diethylenetriamine pentaacetic acid (Gd‐DTPA) in the whole mouse brain was demonstrated ( n = 5).
Results
Phantom studies confirmed accurate T 1 and T 2 measurements by 3D MRF with an undersampling factor of up to 48. Dynamic contrast‐enhanced MRF scans achieved a spatial resolution of 192 × 192 × 500 μm 3 and a temporal resolution of 4.3 min, allowing for the analysis and comparison of dynamic changes in concentration and transport kinetics of intracisternally infused Gd‐DTPA across brain regions. The sequence also enabled highly repeatable, high‐resolution T 1 and T 2 mapping of the whole mouse brain (192 × 192 × 250 μm 3 ) in 30 min.
Conclusion
We present the first dynamic and multi‐parametric approach for quantitatively tracking contrast agent transport in the mouse brain using 3D MRF.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA.
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.
- Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA.
- Department of Pediatrics, Case Western Reserve University, Cleveland, Ohio, USA.
- Department of Physiology and Biophysics, Case Western Reserve University, Cleveland, Ohio, USA.
ORCID profiles: Yuran Zhu, Guanhua Wang, Walter Zhao, Christina J MacAskill, Andrew Dupuis, Mark A Griswold, Dan Ma, Chris A Flask, Xin Yu
Funding
- NIGMS NIH HHS
- American Heart Association
- NCATS NIH HHS
- NINDS NIH HHS
- NIBIB NIH HHS
Cite
APA
Zhu, Y., Wang, G., Gu, Y., Zhao, W., Lu, J., Zhu, J., MacAskill, C. J., Dupuis, A., Griswold, M. A., Ma, D., Flask, C. A., & Yu, X. (2025). 3D MR fingerprinting for dynamic contrast‐enhanced imaging of whole mouse brain. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30253
Vancouver
Zhu Y, Wang G, Gu Y, Zhao W, Lu J, Zhu J, et al. 3D MR fingerprinting for dynamic contrast‐enhanced imaging of whole mouse brain. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30253
BibTeX
@article{Zhu2025,
author = {Zhu, Yuran and Wang, Guanhua and Gu, Yuning and Zhao, Walter and Lu, Jiahao and Zhu, Junqing and MacAskill, Christina J and Dupuis, Andrew and Griswold, Mark A and Ma, Dan and Flask, Chris A and Yu, Xin},
title = {3D MR fingerprinting for dynamic contrast‐enhanced imaging of whole mouse brain},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30253}
}