EUVIMEDOpdag EUVIMED
Crossref

Improved motion correction in brain MRI using 3D radial trajectory and projection moment analysis

Bowen Li iD, Huajun She

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.30159 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2024. Written by Bowen Li and 1 co-authors. Institution: School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China. Major MEDLINE topics: Magnetic Resonance Imaging, Brain, Imaging, Three-Dimensional, Algorithms. Cited 4 times so far (Crossref); 43 references. Funded by: Shanghai Science and Technology Commission Explorer Program, Shanghai Jiao Tong University Scientific and Technological Innovation Funds.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

To develop a generalized rigid body motion correction method in 3D radial brain MRI to deal with continuous motion pattern through projection moment analysis.

Methods

An assumption was made that the multichannel coil moves with the head, which was achieved by using a flexible head coil. A two‐step motion correction scheme was proposed to directly extract the motion parameters from the acquired k‐space data using the analysis of center‐of‐mass with high noise robustness, which were used for retrospective motion correction. A recursive least‐squares model was introduced to recursively estimate the motion parameters for every single spoke, which used the smoothness of motion and resulted in high temporal resolution and low computational cost. Five volunteers were scanned at 3 T using a 3D radial multidimensional golden‐means trajectory with instructed motion patterns. The performance was tested through both simulation and in vivo experiments. Quantitative image quality metrics were calculated for comparison.

Results

The proposed method showed good accuracy and precision in both translation and rotation estimation. A better result was achieved using the proposed two‐step correction compared to traditional one‐step correction without significantly increasing computation time. Retrospective correction showed substantial improvements in image quality among all scans, even for stationary scans.

Conclusions

The proposed method provides an easy, robust, and time‐efficient tool for motion correction in brain MRI, which may benefit clinical diagnosis of uncooperative patients as well as scientific MRI researches.

Subjects

MeSH terms (MEDLINE)

Magnetic Resonance ImagingBrainImaging, Three-DimensionalAlgorithmsMotionHumansArtifactsImage Processing, Computer-AssistedComputer SimulationRetrospective StudiesReproducibility of ResultsAdultImage Enhancement

Author keywords

3D radialcenter‐of‐massmotion correctionprojection momentrecursive least‐squares

Authors and institutions

  • School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
  • National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, Shanghai Jiao Tong University, Shanghai, China.

ORCID profiles: Bowen Li

Funding

  • Shanghai Science and Technology Commission Explorer Program
  • Shanghai Jiao Tong University Scientific and Technological Innovation Funds

Cite

APA

Li, B., & She, H. (2024). Improved motion correction in brain MRI using 3D radial trajectory and projection moment analysis. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30159

Vancouver

Li B, She H. Improved motion correction in brain MRI using 3D radial trajectory and projection moment analysis. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30159

BibTeX
@article{Li2024,
  author = {Li, Bowen and She, Huajun},
  title = {Improved motion correction in brain MRI using 3D radial trajectory and projection moment analysis},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30159}
}
Start for free →