EUVIMEDOpdag EUVIMED
Open access

Effect of particle size on liver MRI R2* relaxometry: Monte Carlo simulation and phantom studies

Xiaoben Li iD, Changqing Wang iD, Jinhong Huang iD, Scott B Reeder iD, Diego Hernando iD

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.30154 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2024. Written by Xiaoben Li and 4 co-authors. Institution: School of Biomedical Engineering, Anhui Medical University, Hefei, China. Major MEDLINE topics: Monte Carlo Method, Phantoms, Imaging, Magnetic Resonance Imaging, Particle Size. Cited 1 times so far (Crossref); 38 references. The full text is freely available in PubMed Central. Funded by: NIH HHS, NIDDK NIH HHS, National Natural Science Foundation of China.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

To investigate the effect of particle size on liver by Monte Carlo simulation and phantom studies at both 1.5 T and 3.0 T.

Methods

Two kinds of particles (i.e., iron sphere and fat droplet) with varying sizes were considered separately in simulation and phantom studies. MRI signals were synthesized and analyzed for predicting , based on simulations by incorporating virtual liver model, particle distribution, magnetic field generation, and proton movement into phase accrual. In the phantom study, iron‐water and fat‐water phantoms were constructed, and each phantom contained 15 separate vials with combinations of five particle concentrations and three particle sizes. measurements in the phantom were made at both 1.5 T and 3.0 T. Finally, differences in predictions or measurements were evaluated across varying particle sizes.

Results

In the simulation study, strong linear and positively correlated relationships were observed between predictions and particle concentrations across varying particle sizes and magnetic field strengths (). The relationships were affected by iron sphere size (), where smaller iron sphere size yielded higher predicted , whereas fat droplet size had no effect on predictions () for constant total fat concentration. Similarly, the phantom study showed that measurements were relatively sensitive to iron sphere size () unlike fat droplet size ().

Conclusion

Liver is affected by iron sphere size, but is relatively unaffected by fat droplet size. These findings may lead to an improved understanding of the underlying mechanisms of relaxometry in vivo, and enable improved quantitative MRI phantom design.

Subjects

MeSH terms (MEDLINE)

Monte Carlo MethodPhantoms, ImagingMagnetic Resonance ImagingParticle SizeLiverComputer SimulationHumans

Author keywords

Monte Carlo simulationsfat dropletironliver R2*particle sizephantom

Authors and institutions

  • School of Biomedical Engineering, Anhui Medical University, Hefei, China.
  • College of Mathematics and Computer Sciences, Gannan Normal University, Ganzhou, China.
  • Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA.
  • Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA.
  • Department of Biomedical Engineering, University of Wisconsin, Madison, Wisconsin, USA.
  • Department of Medicine, University of Wisconsin, Madison, Wisconsin, USA.

ORCID profiles: Xiaoben Li, Changqing Wang, Jinhong Huang, Scott B Reeder, Diego Hernando

Funding

  • NIH HHS
  • NIDDK NIH HHS
  • National Natural Science Foundation of China
  • NIBIB NIH HHS
  • Grants for Scientific Research of BSKY from Anhui Medical University
  • Anhui Provincial Natural Science Foundation
  • Natural Science Research Project of Anhui Educational Committee
  • Natural Science Foundation of Anhui Province

Cite

APA

Li, X., Wang, C., Huang, J., Reeder, S. B., & Hernando, D. (2024). Effect of particle size on liver MRI R2* relaxometry: Monte Carlo simulation and phantom studies. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30154

Vancouver

Li X, Wang C, Huang J, Reeder SB, Hernando D. Effect of particle size on liver MRI R2* relaxometry: Monte Carlo simulation and phantom studies. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30154

BibTeX
@article{Li2024,
  author = {Li, Xiaoben and Wang, Changqing and Huang, Jinhong and Reeder, Scott B and Hernando, Diego},
  title = {Effect of particle size on liver MRI R2* relaxometry: Monte Carlo simulation and phantom studies},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30154}
}
Start for free →