EUVIMEDSkopri EUVIMED
Open access · CC BY 4.0

Fully automated planning for anatomical fetal brain MRI on 0.55T

Sara Neves Silva iD, Sarah McElroy iD, Jordina Aviles Verdera iD, Kathleen Colford, Kamilah St Clair, Raphael Tomi-Tricot, Alena Uus iD, Valéry Ozenne, Megan Hall, Lisa Story, Kuberan Pushparajah, Mary A Rutherford and 2 more

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.30122 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2024. Written by Sara Neves Silva and 13 co-authors. Institution: Centre for the Developing Brain, School of Biomedical Engineering & Imaging Sciences, King's College London, London, UK. Major MEDLINE topics: Brain, Magnetic Resonance Imaging, Fetus, Image Processing, Computer-Assisted. Cited 18 times so far (Crossref); 28 references. The full text is freely available (open access, CC BY 4.0). Funded by: Deutsche Forschungsgemeinschaft, EPSRC Research Council DTP, Health Services and Delivery Research Programme.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Purpose

Widening the availability of fetal MRI with fully automatic real‐time planning of radiological brain planes on 0.55T MRI.

Methods

Deep learning‐based detection of key brain landmarks on a whole‐uterus echo planar imaging scan enables the subsequent fully automatic planning of the radiological single‐shot Turbo Spin Echo acquisitions. The landmark detection pipeline was trained on over 120 datasets from varying field strength, echo times, and resolutions and quantitatively evaluated. The entire automatic planning solution was tested prospectively in nine fetal subjects between 20 and 37 weeks. A comprehensive evaluation of all steps, the distance between manual and automatic landmarks, the planning quality, and the resulting image quality was conducted.

Results

Prospective automatic planning was performed in real‐time without latency in all subjects. The landmark detection accuracy was 4.2 2.6 mm for the fetal eyes and 6.5 3.2 for the cerebellum, planning quality was 2.4/3 (compared to 2.6/3 for manual planning) and diagnostic image quality was 2.2 compared to 2.1 for manual planning.

Conclusions

Real‐time automatic planning of all three key fetal brain planes was successfully achieved and will pave the way toward simplifying the acquisition of fetal MRI thereby widening the availability of this modality in nonspecialist centers.

Subjects

MeSH terms (MEDLINE)

BrainMagnetic Resonance ImagingFetusImage Processing, Computer-AssistedHumansFemalePregnancyDeep LearningPrenatal DiagnosisProspective StudiesEcho-Planar ImagingAlgorithmsImage Interpretation, Computer-Assisted

Author keywords

T2* relaxometryfetal MRIfetal brain developmentmotion correctionmotion detectiontracking

Authors and institutions

  • Centre for the Developing Brain, School of Biomedical Engineering & Imaging Sciences, King's College London, London, UK.
  • Biomedical Engineering Department, School of Biomedical Engineering & Imaging Sciences, King's College London, London, UK.
  • MR Research Collaborations, Siemens Healthcare Limited, Camberley, UK.
  • CNRS, CRMSB, UMR 5536, IHU Liryc, Université de Bordeaux, Bordeaux, France.
  • Department of Women & Children's Health, King's College London, London, UK.
  • Smart Imaging Lab, Radiological Institute, Friedrich-Alexander University Erlangen-Nuremberg, Erlangen, Germany.

ORCID profiles: Sara Neves Silva, Sarah McElroy, Jordina Aviles Verdera, Alena Uus, Jana Hutter

Funding

  • Deutsche Forschungsgemeinschaft
  • EPSRC Research Council DTP
  • Health Services and Delivery Research Programme
  • Wellcome Trust Collaboration in Science
  • UK Research and Innovation
  • Wellcome EPSRC Centre for Medical Engineering
  • Medical Research Council (MRC)

Cite

APA

Neves Silva, S., McElroy, S., Aviles Verdera, J., Colford, K., St Clair, K., Tomi-Tricot, R., Uus, A., Ozenne, V., Hall, M., Story, L., Pushparajah, K., Rutherford, M. A., Hajnal, J. V., & Hutter, J. (2024). Fully automated planning for anatomical fetal brain MRI on 0.55T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30122

Vancouver

Neves Silva S, McElroy S, Aviles Verdera J, Colford K, St Clair K, Tomi-Tricot R, et al. Fully automated planning for anatomical fetal brain MRI on 0.55T. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30122

BibTeX
@article{NevesSilva2024,
  author = {Neves Silva, Sara and McElroy, Sarah and Aviles Verdera, Jordina and Colford, Kathleen and St Clair, Kamilah and Tomi-Tricot, Raphael and Uus, Alena and Ozenne, Valéry and Hall, Megan and Story, Lisa and Pushparajah, Kuberan and Rutherford, Mary A and Hajnal, Joseph V and Hutter, Jana},
  title = {Fully automated planning for anatomical fetal brain MRI on 0.55T},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30122}
}
Start for free →