EUVIMEDOpdag EUVIMED
Open access

Robust multishot diffusion‐weighted imaging of the abdomen with region‐based shot rejection

Philip K Lee iD, Xuetong Zhou iD, Brian A Hargreaves

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.30102 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2024. Written by Philip K Lee and 2 co-authors. Institution: Radiology, Stanford University, Stanford, California, USA. Major MEDLINE topics: Diffusion Magnetic Resonance Imaging, Abdomen, Algorithms, Artifacts. Cited 6 times so far (Crossref); 44 references. The full text is freely available in PubMed Central. Funded by: NCI NIH HHS, NIBIB NIH HHS, GE Healthcare.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

Diffusion‐weighted (DW) imaging provides a useful clinical contrast, but is susceptible to motion‐induced dephasing caused by the application of strong diffusion gradients. Phase navigators are commonly used to resolve shot‐to‐shot motion‐induced phase in multishot reconstructions, but poor phase estimates result in signal dropout and Apparent Diffusion Coefficient (ADC) overestimation. These artifacts are prominent in the abdomen, a region prone to involuntary cardiac and respiratory motion. To improve the robustness of DW imaging in the abdomen, region‐based shot rejection schemes that selectively weight regions where the shot‐to‐shot phase is poorly estimated were evaluated.

Methods

Spatially varying weights for each shot, reflecting both the accuracy of the estimated phase and the degree of subvoxel dephasing, were estimated from the phase navigator magnitude images. The weighting was integrated into a multishot reconstruction using different formulations and phase navigator resolutions and tested with different phase navigator resolutions in multishot DW‐echo Planar Imaging acquisitions of the liver and pancreas, using conventional monopolar and velocity‐compensated diffusion encoding. Reconstructed images and ADC estimates were compared qualitatively.

Results

The proposed region‐based shot rejection reduces banding and signal dropout artifacts caused by physiological motion in the liver and pancreas. Shot rejection allows conventional monopolar diffusion encoding to achieve median ADCs in the pancreas comparable to motion‐compensated diffusion encoding, albeit with a greater spread of ADCs.

Conclusion

Region‐based shot rejection is a linear reconstruction that improves the motion robustness of multi‐shot DWI and requires no sequence modifications.

Subjects

MeSH terms (MEDLINE)

Diffusion Magnetic Resonance ImagingAbdomenAlgorithmsArtifactsHumansImage Processing, Computer-AssistedPancreasLiverImage Interpretation, Computer-AssistedReproducibility of ResultsMotionEcho-Planar ImagingImage EnhancementAdult

Author keywords

diffusion MRIimage reconstructionlinear systems

Authors and institutions

  • Radiology, Stanford University, Stanford, California, USA.
  • Bioengineering, Stanford University, Stanford, California, USA.
  • Electrical Engineering, Stanford University, Stanford, California, USA.

ORCID profiles: Philip K Lee, Xuetong Zhou

Funding

  • NCI NIH HHS
  • NIBIB NIH HHS
  • GE Healthcare
  • NIH HHS
  • National Institutes of Health

Cite

APA

Lee, P. K., Zhou, X., & Hargreaves, B. A. (2024). Robust multishot diffusion‐weighted imaging of the abdomen with region‐based shot rejection. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30102

Vancouver

Lee PK, Zhou X, Hargreaves BA. Robust multishot diffusion‐weighted imaging of the abdomen with region‐based shot rejection. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30102

BibTeX
@article{Lee2024,
  author = {Lee, Philip K and Zhou, Xuetong and Hargreaves, Brian A},
  title = {Robust multishot diffusion‐weighted imaging of the abdomen with region‐based shot rejection},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30102}
}
Start for free →