EUVIMEDEUVIMED entdecken
Open Access

Specific and rapid guanidinium CEST imaging using double saturation power and QUASS analysis in a rodent model of global ischemia

Iris Y Zhou iD, Yang Ji iD, Yu Zhao iD, Malvika Viswanathan iD, Phillip Zhe Sun iD, Zhongliang Zu iD

Magnetic Resonance in Medicine · 2024-04 · 91 (4) · 1512-1527

DOI: 10.1002/mrm.29960 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 14.12.2023. Verfasst von Iris Y Zhou und 5 weiteren Autor:innen. Beteiligte Einrichtung: Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown,…. Hauptthemen laut MEDLINE: Brain, Stroke. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 65 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, NIH HHS, NHLBI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Guanidinium CEST is sensitive to metabolic changes and pH variation in ischemia, and it can offer advantages over conventional pH‐sensitive amide proton transfer (APT) imaging by providing hyperintense contrast in stroke lesions. However, quantifying guanidinium CEST is challenging due to multiple overlapping components and a close frequency offset from water. This study aims to evaluate the applicability of a new rapid and model‐free CEST quantification method using double saturation power, termed DSP‐CEST, for isolating the guanidinium CEST effect from confounding factors in ischemia. To further reduce acquisition time, the DSP‐CEST was combined with a quasi‐steady state (QUASS) CEST technique to process non‐steady‐state CEST signals.

Methods

The specificity and accuracy of the DSP‐CEST method in quantifying the guanidinium CEST effect were assessed by comparing simulated CEST signals with/without the contribution from confounding factors. The feasibility of this method for quantifying guanidinium CEST was evaluated in a rat model of global ischemia induced by cardiac arrest and compared to a conventional multiple‐pool Lorentzian fit method.

Results

The DSP‐CEST method was successful in removing all confounding components and quantifying the guanidinium CEST signal increase in ischemia. This suggests that the DSP‐CEST has the potential to provide hyperintense contrast in stroke lesions. Additionally, the DSP‐CEST was shown to be a rapid method that does not require the acquisition of the entire or a portion of the CEST Z‐spectrum that is required in conventional model‐based fitting approaches.

Conclusion

This study highlights the potential of DSP‐CEST as a valuable tool for rapid and specific detection of viable tissues.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BrainStrokeRatsAnimalsMagnetic Resonance ImagingGuanidineRodentiaIschemiaAmides

Stichwörter der Autor:innen

chemical exchange saturation transfer (CEST)guanidinestroke

Substanzen

GuanidineAmides

Autor:innen und Institutionen

  • Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts, USA.
  • Wellcome Centre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.
  • Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Department of Radiology, West China Hospital of Sichuan University, Chengdu, China.
  • Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee, USA.

ORCID-Profile: Iris Y Zhou, Yang Ji, Yu Zhao, Malvika Viswanathan, Phillip Zhe Sun, Zhongliang Zu

Förderung

  • NIBIB NIH HHS
  • NIH HHS
  • NHLBI NIH HHS
  • National Institutes of Health

Zitieren

APA

Zhou, I. Y., Ji, Y., Zhao, Y., Viswanathan, M., Sun, P. Z., & Zu, Z. (2024). Specific and rapid guanidinium CEST imaging using double saturation power and QUASS analysis in a rodent model of global ischemia. Magnetic Resonance in Medicine, 91(4), 1512-1527. https://doi.org/10.1002/mrm.29960

Vancouver

Zhou IY, Ji Y, Zhao Y, Viswanathan M, Sun PZ, Zu Z. Specific and rapid guanidinium CEST imaging using double saturation power and QUASS analysis in a rodent model of global ischemia. Magnetic Resonance in Medicine. 2024;91(4):1512-1527. doi:10.1002/mrm.29960

BibTeX
@article{Zhou2024,
  author = {Zhou, Iris Y and Ji, Yang and Zhao, Yu and Viswanathan, Malvika and Sun, Phillip Zhe and Zu, Zhongliang},
  title = {Specific and rapid guanidinium CEST imaging using double saturation power and QUASS analysis in a rodent model of global ischemia},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  volume = {91},
  number = {4},
  pages = {1512--1527},
  doi = {10.1002/mrm.29960}
}
Kostenlos starten →