Water removal in MR spectroscopic imaging with Casorati singular value decomposition
Magnetic Resonance in Medicine · 2024
DOI: 10.1002/mrm.29959 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Amirmohammad Shamaei und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Scientific Instruments of the Czech Academy of Sciences, Brno, Czech Republic. Hauptthemen laut MEDLINE: Water, Magnetic Resonance Imaging. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Czech Academy of Sciences, Institute of Scientific Instruments, ISI-MR Facility of the Czech-BioImaging Infrastructure, The Marie Sklodowska-Curie Grant Agreement (INSPiRE-MED).
Abstract (Originalsprache)
Purpose
Water removal is one of the computational bottlenecks in the processing of high‐resolution MRSI data. The purpose of this work is to propose an approach to reduce the computing time required for water removal in large MRS data.
Methods
In this work, we describe a singular value decomposition–based approach that uses the partial position‐time separability and the time‐domain linear predictability of MRSI data to reduce the computational time required for water removal. Our approach arranges MRS signals in a Casorati matrix form, applies low‐rank approximations utilizing singular value decomposition, removes residual water from the most prominent left‐singular vectors, and finally reconstructs the water‐free matrix using the processed left‐singular vectors.
Results
We have demonstrated the effectiveness of our proposed algorithm for water removal using both simulated and in vivo data. The proposed algorithm encompasses a pip‐installable tool ( https://pypi.org/project/CSVD/ ), available on GitHub ( https://github.com/amirshamaei/CSVD ), empowering researchers to use it in future studies. Additionally, to further promote transparency and reproducibility, we provide comprehensive code for result replication.
Conclusions
The findings of this study suggest that the proposed method is a promising alternative to existing water removal methods due to its low processing time and good performance in removing water signals.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institute of Scientific Instruments of the Czech Academy of Sciences, Brno, Czech Republic.
- Department of Electrical and Software Engineering, Schulich School of Engineering, University of Calgary, Calgary, Alberta, Canada.
- MR Methodology, Department of Interventional Neuroradiology, University of Bern, Bern, Switzerland.
- Department of Biomedical Research, University of Bern, Bern, Switzerland.
- Translational Imaging Center (TIC), Swiss Institute of Translational Entrepreneurial Medicine, Bern, Switzerland.
ORCID-Profile: Amirmohammad Shamaei, Zenon Starcuk
Förderung
- Czech Academy of Sciences, Institute of Scientific Instruments
- ISI-MR Facility of the Czech-BioImaging Infrastructure
- The Marie Sklodowska-Curie Grant Agreement (INSPiRE-MED)
- Akademie Věd České Republiky
Zitieren
APA
Shamaei, A., Starcukova, J., Rizzo, R., & Starcuk, Z. (2024). Water removal in MR spectroscopic imaging with Casorati singular value decomposition. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29959
Vancouver
Shamaei A, Starcukova J, Rizzo R, Starcuk Z. Water removal in MR spectroscopic imaging with Casorati singular value decomposition. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.29959
BibTeX
@article{Shamaei2024,
author = {Shamaei, Amirmohammad and Starcukova, Jana and Rizzo, Rudy and Starcuk, Zenon},
title = {Water removal in MR spectroscopic imaging with Casorati singular value decomposition},
journal = {Magnetic Resonance in Medicine},
year = {2024},
doi = {10.1002/mrm.29959}
}
EUVIMED