CEST and nuclear Overhauser enhancement imaging with deep learning–extrapolated semisolid magnetization transfer reference: Scan‐rescan reproducibility and reliability studies
Magnetic Resonance in Medicine · 2024
DOI: 10.1002/mrm.29937 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Hye-Young Heo und 4 weiteren Autor:innen. Beteiligte Einrichtung: The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Baltimore, Maryland, USA. Hauptthemen laut MEDLINE: Deep Learning, Brain Neoplasms. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NIBIB NIH HHS, NINDS NIH HHS, NIH HHS.
Abstract (Originalsprache)
Purpose
To develop a novel MR physics‐driven, deep‐learning, extrapolated semisolid magnetization transfer reference (DeepEMR) framework to provide fast, reliable magnetization transfer contrast (MTC) and CEST signal estimations, and to determine the reproducibility and reliability of the estimates from the DeepEMR.
Methods
A neural network was designed to predict a direct water saturation and MTC‐dominated signal at a certain CEST frequency offset using a few high‐frequency offset features in the Z‐spectrum. The accuracy, scan‐rescan reproducibility, and reliability of MTC, CEST, and relayed nuclear Overhauser enhancement (rNOE) signals estimated from the DeepEMR were evaluated on numerical phantoms and in heathy volunteers at 3 T. In addition, we applied the DeepEMR method to brain tumor patients and compared tissue contrast with other CEST calculation metrics.
Results
The DeepEMR method demonstrated a high degree of accuracy in the estimation of reference MTC signals at ±3.5 ppm for APT and rNOE imaging, and computational efficiency (˜190‐fold) compared with a conventional fitting approach. In addition, the DeepEMR method achieved high reproducibility and reliability (intraclass correlation coefficient = 0.97, intersubject coefficient of variation = 3.5%, and intrasubject coefficient of variation = 1.3%) of the estimation of MTC signals at ±3.5 ppm. In tumor patients, DeepEMR‐based amide proton transfer images provided higher tumor contrast than a conventional MT ratio asymmetry image, particularly at higher B 1 strengths (>1.5 μT), with a distinct delineation of the tumor core from normal tissue or peritumoral edema.
Conclusion
The DeepEMR approach is feasible for measuring clean APT and rNOE effects in longitudinal and cross‐sectional studies with low scan‐rescan variability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Baltimore, Maryland, USA.
ORCID-Profile: Hye-Young Heo, Jinyuan Zhou
Förderung
- NIBIB NIH HHS
- NINDS NIH HHS
- NIH HHS
- National Institutes of Health
Zitieren
APA
Heo, H. Y., Singh, M., Yedavalli, V., Jiang, S., & Zhou, J. (2024). CEST and nuclear Overhauser enhancement imaging with deep learning–extrapolated semisolid magnetization transfer reference: Scan‐rescan reproducibility and reliability studies. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29937
Vancouver
Heo HY, Singh M, Yedavalli V, Jiang S, Zhou J. CEST and nuclear Overhauser enhancement imaging with deep learning–extrapolated semisolid magnetization transfer reference: Scan‐rescan reproducibility and reliability studies. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.29937
BibTeX
@article{Heo2024,
author = {Heo, Hye-Young and Singh, Munendra and Yedavalli, Vivek and Jiang, Shanshan and Zhou, Jinyuan},
title = {CEST and nuclear Overhauser enhancement imaging with deep learning–extrapolated semisolid magnetization transfer reference: Scan‐rescan reproducibility and reliability studies},
journal = {Magnetic Resonance in Medicine},
year = {2024},
doi = {10.1002/mrm.29937}
}