EUVIMEDEUVIMED entdecken
Crossref

Deep learning approach for DCE-MRI parameter estimation: Evaluating signal intensity and concentration-time curve-based convolution-neural-networks

Piyush Kumar Prajapati, Rakesh Kumar Gupta, Anup Singh

Magnetic Resonance Imaging · 2026

DOI: 10.1016/j.mri.2025.110559 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2026. Verfasst von Piyush Kumar Prajapati und 2 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Biomedical Engineering, Indian Institute of Technology Delhi, New Delhi, India. Hauptthemen laut MEDLINE: Deep Learning, Magnetic Resonance Imaging, Brain Neoplasms, Glioma. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 50 Literaturangaben. Gefördert von: Department of Science and Technology, Ministry of Science and Technology, India, Indian Council of Medical Research, Science and Engineering Research Board.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Dynamic contrast-enhanced MRI (DCE-MRI) is common technique for assessing tissue perfusion and permeability in brain tumors (e.g., gliomas), using generalized tracer kinetic (GTK) analysis. However, conventional non-linear least squares (NLLS) methods are computationally expensive and sensitive to noise and protocol variations (e.g., temporal resolution, flip angle), leading to inconsistent parameter estimates. Most recent deep learning methods use signal-intensity and pre-contrast T1, without addressing acquisition protocol variation effects. We propose CNNCON, a concentration curve-based convolutional neural network-based approach for GTK parameter estimation, designed to adapt to various DCE-MRI protocols with faster processing and investigate its accuracy and robustness to protocol variations. CNNCON was trained on synthetic data with protocol variations, and fine-tuned on 72 glioma patients(grade 2-4). Validation was performed on 18 test patients and two external datasets: cross-scanner(n = 9, 1.5 T) and cross-institutional(n = 6, different hospital). Performance was compared against NLLS and AIF-TK Net. CNNCON achieved mean absolute errors of 111 ± 70 × 10-5 min-1, 134 ± 53 × 10-5, and 133 ± 57 × 10-4 for Ktrans, vp and ve, respectively, with no significant difference from NLLS(p > 0.05), while reducing computational time from 15 min to 17 s. External validation demonstrated consistent performance across scanner and institutions. CNNCON showed 2-3× better accuracy than AIF-TK Net and equivalent diagnostic capability for tumor grading (AUC = 0.89). Correlation with NLLS exceed 0.97 in normal tissues. The concentration-based approach provides superior robustness to protocol variations, validated across multiple centers, enabling consistent application of perfusion imaging biomarkers in clinical practice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningMagnetic Resonance ImagingBrain NeoplasmsGliomaContrast MediaNeural Networks, ComputerImage Processing, Computer-AssistedHumansBrainMaleReproducibility of ResultsFemaleImage Interpretation, Computer-AssistedMiddle AgedAdultAlgorithmsDynamic Contrast Enhanced Magnetic Resonance Imaging

Stichwörter der Autor:innen

Convolutional neural networkDCE-MRIGliomasProtocol variationTracer kinetic modeling

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Centre for Biomedical Engineering, Indian Institute of Technology Delhi, New Delhi, India.
  • Department of Radiology, Fortis Memorial Research Institute, Gurugram, India.
  • Centre for Biomedical Engineering, Indian Institute of Technology Delhi, New Delhi, India; Yardi School of Artificial Intelligence, Indian Institute of Technology Delhi, New Delhi, India; Department of Biomedical Engine…

Förderung

  • Department of Science and Technology, Ministry of Science and Technology, India
  • Indian Council of Medical Research
  • Science and Engineering Research Board

Zitieren

APA

Prajapati, P. K., Gupta, R. K., & Singh, A. (2026). Deep learning approach for DCE-MRI parameter estimation: Evaluating signal intensity and concentration-time curve-based convolution-neural-networks. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2025.110559

Vancouver

Prajapati PK, Gupta RK, Singh A. Deep learning approach for DCE-MRI parameter estimation: Evaluating signal intensity and concentration-time curve-based convolution-neural-networks. Magnetic Resonance Imaging. 2026. doi:10.1016/j.mri.2025.110559

BibTeX
@article{Prajapati2026,
  author = {Prajapati, Piyush Kumar and Gupta, Rakesh Kumar and Singh, Anup},
  title = {Deep learning approach for DCE-MRI parameter estimation: Evaluating signal intensity and concentration-time curve-based convolution-neural-networks},
  journal = {Magnetic Resonance Imaging},
  year = {2026},
  doi = {10.1016/j.mri.2025.110559}
}
Kostenlos starten →