EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Facilitating diffusion tensor imaging of the brain during continuous gross head motion with first and second order motion compensating diffusion gradients

Danielle Kara iD, Katherine Koenig, Mark Lowe, Christopher T Nguyen iD, Ken Sakaie

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.29924 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2024. Written by Danielle Kara and 4 co-authors. Institution: Cardiovascular Innovation Research Center, Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA. Major MEDLINE topics: Diffusion Tensor Imaging, Brain. Cited 2 times so far (Crossref); 38 references. The full text is freely available (open access, CC BY 4.0). Funded by: NIBIB NIH HHS, NHLBI NIH HHS, NIH HHS.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

To demonstrate the feasibility of motion compensating diffusion gradient schemes in the acquisition of quality diffusion tensor images (DTI) of the brain during continuous gross head motion.

Methods

Five healthy subjects were scanned using a clinical 3 T MRI with and without continuous head motion. For one volunteer, DTI data was acquired using standard (M0) diffusion‐weighted (DW) gradients, and first (M1) and second (M2) order gradient schemes that were previously developed for use in cardiac DTI. In four additional volunteers, DTI data was acquired with M0 and M2 gradients. DTI parameters were calculated and compared with established retrospective motion corrections.

Results

In the absence of motion, DTI parameters calculated from M0, M1, and M2 data were consistent. In the presence of motion, up to 44% of DW images acquired with M0 gradients were corrupted by signal dropout, compared to 0% of the M2 images. In voxelwise comparisons, DTI parameters calculated using motion‐M0 data were elevated compared to reference data. Retrospective corrections for extreme motion applied to motion‐M0 data did not improve consistency with reference data in cases where motion corrupted >15% of DW images. In contrast, DTI parameters calculated with motion‐M2 data were consistent with reference data.

Conclusion

This proof‐of‐principle study demonstrates that motion compensating diffusion gradients can mitigate artifacts because of continuous motion in DTI of the brain and offers promise for improved DTI accessibility. Further study will be necessary to determine the robustness of the approach in patient populations with high susceptibility to head motion.

Subjects

MeSH terms (MEDLINE)

Diffusion Tensor ImagingBrainHumansRetrospective StudiesMotionMagnetic Resonance ImagingDiffusion Magnetic Resonance Imaging

Author keywords

braindiffusion tensor imagingmotion compensation

Authors and institutions

  • Cardiovascular Innovation Research Center, Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA.
  • Imaging Sciences, Imaging Institute, Cleveland Clinic, Cleveland, Ohio, USA.
  • Biomedical Engineering, Lerner Research Institute, Cleveland Clinic and Case Western Reserve University, Cleveland, Ohio, USA.

ORCID profiles: Danielle Kara, Christopher T Nguyen

Funding

  • NIBIB NIH HHS
  • NHLBI NIH HHS
  • NIH HHS
  • National Institutes of Health

Cite

APA

Kara, D., Koenig, K., Lowe, M., Nguyen, C. T., & Sakaie, K. (2024). Facilitating diffusion tensor imaging of the brain during continuous gross head motion with first and second order motion compensating diffusion gradients. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29924

Vancouver

Kara D, Koenig K, Lowe M, Nguyen CT, Sakaie K. Facilitating diffusion tensor imaging of the brain during continuous gross head motion with first and second order motion compensating diffusion gradients. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.29924

BibTeX
@article{Kara2024,
  author = {Kara, Danielle and Koenig, Katherine and Lowe, Mark and Nguyen, Christopher T and Sakaie, Ken},
  title = {Facilitating diffusion tensor imaging of the brain during continuous gross head motion with first and second order motion compensating diffusion gradients},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.29924}
}
Start for free →