EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

ISMRM Open Science Initiative for Perfusion Imaging (OSIPI): ASL pipeline inventory

Hongli Fan, Henk J M M Mutsaerts iD, Udunna Anazodo, Daniel Arteaga, Koen P A Baas, Charlotte Buchanan, Aldo Camargo, Vera C Keil, Zixuan Lin, Thomas Lindner iD, Lydiane Hirschler iD, Jian Hu iD und 5 weitere

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.29869 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Hongli Fan und 16 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Johns Hopkins School of Medicine, Baltimore, Baltimore, Maryland, USA. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted, Imaging, Three-Dimensional. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIH HHS, NIA NIH HHS, NHLBI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To create an inventory of image processing pipelines of arterial spin labeling (ASL) and list their main features, and to evaluate the capability, flexibility, and ease of use of publicly available pipelines to guide novice ASL users in selecting their optimal pipeline.

Methods

Developers self‐assessed their pipelines using a questionnaire developed by the Task Force 1.1 of the ISMRM Open Science Initiative for Perfusion Imaging. Additionally, each publicly available pipeline was evaluated by two independent testers with basic ASL experience using a scoring system created for this purpose.

Results

The developers of 21 pipelines filled the questionnaire. Most pipelines are free for noncommercial use (n = 18) and work with the standard NIfTI (Neuroimaging Informatics Technology Initiative) data format (n = 15). All pipelines can process standard 3D single postlabeling delay pseudo‐continuous ASL images and primarily differ in their support of advanced sequences and features. The publicly available pipelines (n = 9) were included in the independent testing, all of them being free for noncommercial use. The pipelines, in general, provided a trade‐off between ease of use and flexibility for configuring advanced processing options.

Conclusion

Although most ASL pipelines can process the common ASL data types, only some (namely, ASLPrep, ASLtbx, BASIL/Quantiphyse, ExploreASL, and MRICloud) are well‐documented, publicly available, support multiple ASL types, have a user‐friendly interface, and can provide a useful starting point for ASL processing. The choice of an optimal pipeline should be driven by specific data to be processed and user experience, and can be guided by the information provided in this ASL inventory.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Image Processing, Computer-AssistedImaging, Three-DimensionalSpin LabelsArteriesPerfusion ImagingCerebrovascular CirculationMagnetic Resonance ImagingPerfusion

Stichwörter der Autor:innen

arterial spin labelingautomated processing pipelinecerebral blood flowopen scienceperfusion

Substanzen

Spin Labels

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Johns Hopkins School of Medicine, Baltimore, Baltimore, Maryland, USA.
  • MR Research and Development, Siemens Medical Solutions USA, Inc., Dallas, Texas, USA.
  • Department of Radiology and Nuclear Medicine, Amsterdam University Medical Center, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands.
  • Brain Imaging, Amsterdam Neuroscience, Amsterdam, The Netherlands.
  • Montreal Neurological Institute, McGill University, Montreal, Quebec, Canada.
  • Ascension Saint Thomas Hospital, Nashville, Tennessee, USA.

ORCID-Profile: Henk J M M Mutsaerts, Thomas Lindner, Lydiane Hirschler, Jian Hu, David L Thomas, Jan Petr

Förderung

  • NIH HHS
  • NIA NIH HHS
  • NHLBI NIH HHS
  • Wellcome Trust
  • Canada First Research Excellence Fund
  • European Cooperation in Science and Technology
  • THF
  • Rijksdienst voor Ondernemend Nederland

Zitieren

APA

Fan, H., Mutsaerts, H. J. M. M., Anazodo, U., Arteaga, D., Baas, K. P. A., Buchanan, C., Camargo, A., Keil, V. C., Lin, Z., Lindner, T., Hirschler, L., Hu, J., Padrela, B. E., Taghvaei, M., Thomas, D. L., Dolui, S., & Petr, J. (2024). ISMRM Open Science Initiative for Perfusion Imaging (OSIPI): ASL pipeline inventory. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29869

Vancouver

Fan H, Mutsaerts HJMM, Anazodo U, Arteaga D, Baas KPA, Buchanan C, et al. ISMRM Open Science Initiative for Perfusion Imaging (OSIPI): ASL pipeline inventory. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.29869

BibTeX
@article{Fan2024,
  author = {Fan, Hongli and Mutsaerts, Henk J M M and Anazodo, Udunna and Arteaga, Daniel and Baas, Koen P A and Buchanan, Charlotte and Camargo, Aldo and Keil, Vera C and Lin, Zixuan and Lindner, Thomas and Hirschler, Lydiane and Hu, Jian and Padrela, Beatriz E and Taghvaei, Mohammad and Thomas, David L and Dolui, Sudipto and Petr, Jan},
  title = {ISMRM Open Science Initiative for Perfusion Imaging (OSIPI): ASL pipeline inventory},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.29869}
}
Kostenlos starten →