EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Prospective motion correction for cervical spinal cord MRS

Isaac M Adanyeguh iD, Pierre-Gilles Henry, Dinesh K Deelchand iD

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.29836 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Isaac M Adanyeguh und 2 weiteren Autor:innen. Beteiligte Einrichtung: Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA. Hauptthemen laut MEDLINE: Cervical Cord. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NINDS NIH HHS, NIBIB NIH HHS, NCI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To develop prospective motion correction for single‐voxel MRS in the human cervical spinal cord.

Methods

A motion MR navigator was implemented using reduced field‐of‐view 2D‐selective RF excitation together with EPI readout. A short‐echo semi‐LASER sequence (T E = 30 ms) was updated to incorporate this real‐time image‐based motion navigator, as well as real‐time shim and frequency navigators. Five healthy participants were studied at 3 T with a 64‐channel head–neck receive coil. Single‐voxel MRS data were measured in a voxel located at the C3‐5 vertebrae level. The motion navigator was used to correct for translations in the X ‐ Y plane and was validated by assessing spectral quality with and without prospective correction in the presence of subject motion.

Results

Without prospective correction, motion resulted in severe lipid contamination in the MR spectra. With prospective correction, the quality of spinal cord MR spectra in the presence of motion was similar to that obtained in the absence of motion, with comparable spectral signal‐to‐noise ratio and linewidth and no significant lipid contamination.

Conclusion

Prospective motion and B 0 correction allow acquisition of good‐quality MR spectra in the human cervical spinal cord in the presence of motion. This new technique should facilitate reliable acquisition of spinal cord MR spectra in both research and clinical settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cervical CordHumansProspective StudiesMotionSpinal CordLipidsArtifactsBrainMagnetic Resonance Imaging

Stichwörter der Autor:innen

3 Tprospective motion correctionspectroscopyspinal cord

Substanzen

Lipids

Autor:innen und Institutionen

  • Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA.

ORCID-Profile: Isaac M Adanyeguh, Dinesh K Deelchand

Förderung

  • NINDS NIH HHS
  • NIBIB NIH HHS
  • NCI NIH HHS

Zitieren

APA

Adanyeguh, I. M., Henry, P. G., & Deelchand, D. K. (2024). Prospective motion correction for cervical spinal cord MRS. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29836

Vancouver

Adanyeguh IM, Henry PG, Deelchand DK. Prospective motion correction for cervical spinal cord MRS. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.29836

BibTeX
@article{Adanyeguh2024,
  author = {Adanyeguh, Isaac M and Henry, Pierre-Gilles and Deelchand, Dinesh K},
  title = {Prospective motion correction for cervical spinal cord MRS},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.29836}
}
Kostenlos starten →