Improving magnetic resonance spectroscopy in the brainstem periaqueductal gray using spectral registration
Magnetic Resonance in Medicine · 2024
DOI: 10.1002/mrm.29832 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Laura Sirucek und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chiropractic Medicine, Integrative Spinal Research Group, Balgrist University Hospital, University of Zurich, Zurich, Switzerland. Hauptthemen laut MEDLINE: Periaqueductal Gray, Brain. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universität Zürich.
Abstract (Originalsprache)
Purpose
Functional understanding of the periaqueductal gray (PAG), a clinically relevant brainstem region, can be advanced using 1 H‐MRS. However, the PAG's small size and high levels of physiological noise are methodologically challenging. This study aimed to (1) improve 1 H‐MRS quality in the PAG using spectral registration for frequency and phase error correction; (2) investigate whether spectral registration is particularly useful in cases of greater head motion; and (3) examine metabolite quantification using literature‐based or individual‐based water relaxation times.
Methods
Spectra were acquired in 33 healthy volunteers (50.1 years, SD = 17.19, 18 females) on a 3 T Philipps MR system using a point‐resolved spectroscopy (PRESS) sequence optimized with very selective saturation pulses (OVERPRESS) and voxel‐based flip angle calibration (effective volume of interest size: 8.8 × 10.2 × 12.2 mm 3 ). Spectra were fitted using LCModel and SNR, NAA peak linewidths and Cramér‐Rao lower bounds (CRLBs) were measured after spectral registration and after minimal frequency alignment.
Results
Spectral registration improved SNR by 5% ( p = 0.026, median value post‐correction: 18.0) and spectral linewidth by 23% ( p < 0.001, 4.3 Hz), and reduced the metabolites' CRLBs by 1% to 15% ( p < 0.026). Correlational analyses revealed smaller SNR improvements with greater head motion ( p = 0.010) recorded using a markerless motion tracking system. Higher metabolite concentrations were detected using individual‐based compared to literature‐based water relaxation times ( p < 0.001).
Conclusion
This study demonstrates high‐quality 1 H‐MRS acquisition in the PAG using spectral registration. This shows promise for future 1 H‐MRS studies in the PAG and possibly other clinically relevant brain regions with similar methodological challenges.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chiropractic Medicine, Integrative Spinal Research Group, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
- Neuroscience Center Zurich, University of Zurich, Zurich, Switzerland.
- Department of Forensic Medicine and Imaging, Institute of Forensic Medicine, University of Zurich, Zurich, Switzerland.
- Department of Psychiatry, Psychotherapy, and Psychosomatics, Psychiatric University Hospital Zurich, University of Zurich, Zurich, Switzerland.
ORCID-Profile: Laura Sirucek
Förderung
- Universität Zürich
Zitieren
APA
Sirucek, L., Zoelch, N., & Schweinhardt, P. (2024). Improving magnetic resonance spectroscopy in the brainstem periaqueductal gray using spectral registration. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29832
Vancouver
Sirucek L, Zoelch N, Schweinhardt P. Improving magnetic resonance spectroscopy in the brainstem periaqueductal gray using spectral registration. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.29832
BibTeX
@article{Sirucek2024,
author = {Sirucek, Laura and Zoelch, Niklaus and Schweinhardt, Petra},
title = {Improving magnetic resonance spectroscopy in the brainstem periaqueductal gray using spectral registration},
journal = {Magnetic Resonance in Medicine},
year = {2024},
doi = {10.1002/mrm.29832}
}