Prostate perfusion mapping using Fourier‐transform based velocity‐selective arterial spin labeling: Choice of cutoff velocity and comparison with brain
Magnetic Resonance in Medicine · 2023
DOI: 10.1002/mrm.29695 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2023. Verfasst von Dapeng Liu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA. Hauptthemen laut MEDLINE: Prostate, Magnetic Resonance Angiography. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NHLBI NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
Purpose
To develop velocity selective arterial spin labeling (VSASL) protocols for prostate blood flow (PBF) and prostate blood volume (PBV) mapping.
Methods
Fourier‐transform based velocity‐selective inversion and saturation pulse trains were utilized in VSASL sequences to obtain blood flow and blood volume weighted perfusion signal, respectively. Here four cutoff velocities (V cut = 0.25, 0.50, 1.00, and 1.50 cm/s) for PBF and PBV mapping sequences were evaluated with a parallel implementation in brain for measuring cerebral blood flow (CBF) and cerebral blood volume (CBV) with identical 3D readout. This study was performed at 3T on eight young and middle‐aged healthy subjects comparing both perfusion weighted signal (PWS) and temporal SNR (tSNR).
Results
In contrast to CBF and CBV, the PWS of PBF and PBV were rather unobservable at V cut of 1.00 or 1.50 cm/s and both PWS and tSNR of PBF and PBV considerably increased at the lower V cut , indicating that blood moves much slower in prostate than in brain. Similar to the brain results, the tSNR of PBV‐weighted signal was about two to four times over the corresponding values of PBF‐weighted signal. The results also suggested a trend of reduced vascularity within prostate during aging.
Conclusion
For prostate, a low V cut of 0.25–0.50 cm/s seemed necessary for both PBF and PBV measurements to obtain adequate perfusion signal. As in brain, PBV mapping yielded a higher tSNR than PBF.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA.
ORCID-Profile: Dapeng Liu, Dan Zhu, Feng Xu, Farzad Sedaghat, Qin Qin
Förderung
- NHLBI NIH HHS
- National Institutes of Health
Zitieren
APA
Liu, D., Zhu, D., Xu, F., Sedaghat, F., & Qin, Q. (2023). Prostate perfusion mapping using Fourier‐transform based velocity‐selective arterial spin labeling: Choice of cutoff velocity and comparison with brain. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29695
Vancouver
Liu D, Zhu D, Xu F, Sedaghat F, Qin Q. Prostate perfusion mapping using Fourier‐transform based velocity‐selective arterial spin labeling: Choice of cutoff velocity and comparison with brain. Magnetic Resonance in Medicine. 2023. doi:10.1002/mrm.29695
BibTeX
@article{Liu2023,
author = {Liu, Dapeng and Zhu, Dan and Xu, Feng and Sedaghat, Farzad and Qin, Qin},
title = {Prostate perfusion mapping using Fourier‐transform based velocity‐selective arterial spin labeling: Choice of cutoff velocity and comparison with brain},
journal = {Magnetic Resonance in Medicine},
year = {2023},
doi = {10.1002/mrm.29695}
}
EUVIMED