Data adaptive regularization with reference tissue constraints for liver quantitative susceptibility mapping
Magnetic Resonance in Medicine · 2023-08 · 90 (2) · 385-399
DOI: 10.1002/mrm.29644 ↗At a glance
Journal article in Magnetic Resonance in Medicine, published online on 2023-03-17. Written by Julia V Velikina and 5 co-authors. Institution: Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA. Major MEDLINE topics: Iron, Magnetic Resonance Imaging. Cited 4 times so far (Crossref); 53 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: NIBIB NIH HHS, NIH HHS, NIDDK NIH HHS.
Abstract (original language)
Purpose
To improve repeatability and reproducibility across acquisition parameters and reduce bias in quantitative susceptibility mapping (QSM) of the liver, through development of an optimized regularized reconstruction algorithm for abdominal QSM.
Methods
An optimized approach to estimation of magnetic susceptibility distribution is formulated as a constrained reconstruction problem that incorporates estimates of the input data reliability and anatomical priors available from chemical shift‐encoded imaging. The proposed data‐adaptive method was evaluated with respect to bias, repeatability, and reproducibility in a patient population with a wide range of liver iron concentration (LIC). The proposed method was compared to the previously proposed and validated approach in liver QSM for two multi‐echo spoiled gradient‐recalled echo protocols with different acquisition parameters at 3T. Linear regression was used for evaluation of QSM methods against a reference FDA‐approved ‐based LIC measure and measurements; repeatability/reproducibility were assessed by Bland–Altman analysis.
Results
The data‐adaptive method produced susceptibility maps with higher subjective quality due to reduced shading artifacts. For both acquisition protocols, higher linear correlation with both ‐ and ‐based measurements were observed for the data‐adaptive method ( for , for ) than the standard method ( and ). For both protocols, the data‐adaptive method enabled better test–retest repeatability (repeatability coefficients 0.19/0.30 ppm for the data‐adaptive method, 0.38/0.47 ppm for the standard method) and reproducibility across protocols (reproducibility coefficient 0.28 vs. 0.53ppm) than the standard method.
Conclusions
The proposed data‐adaptive QSM algorithm may enable quantification of LIC with improved repeatability/reproducibility across different acquisition parameters as 3T.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA.
- Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA.
- Department of Biomedical Engineering, University of Wisconsin, Madison, Wisconsin, USA.
- Department of Medicine, University of Wisconsin, Madison, WI, USA.
- Department of Emergency Medicine, University of Wisconsin, Madison, Wisconsin, USA.
ORCID profiles: Julia V Velikina, Ruiyang Zhao, Collin J Buelo, Alexey A Samsonov, Scott B Reeder, Diego Hernando
Funding
- NIBIB NIH HHS
- NIH HHS
- NIDDK NIH HHS
- National Institutes of Health
Cite
APA
Velikina, J. V., Zhao, R., Buelo, C. J., Samsonov, A. A., Reeder, S. B., & Hernando, D. (2023). Data adaptive regularization with reference tissue constraints for liver quantitative susceptibility mapping. Magnetic Resonance in Medicine, 90(2), 385-399. https://doi.org/10.1002/mrm.29644
Vancouver
Velikina JV, Zhao R, Buelo CJ, Samsonov AA, Reeder SB, Hernando D. Data adaptive regularization with reference tissue constraints for liver quantitative susceptibility mapping. Magnetic Resonance in Medicine. 2023;90(2):385-399. doi:10.1002/mrm.29644
BibTeX
@article{Velikina2023,
author = {Velikina, Julia V and Zhao, Ruiyang and Buelo, Collin J and Samsonov, Alexey A and Reeder, Scott B and Hernando, Diego},
title = {Data adaptive regularization with reference tissue constraints for liver quantitative susceptibility mapping},
journal = {Magnetic Resonance in Medicine},
year = {2023},
volume = {90},
number = {2},
pages = {385--399},
doi = {10.1002/mrm.29644}
}
EUVIMED