EUVIMEDOpdag EUVIMED
Open access

Enhanced 129 Xe T 1 relaxation in whole blood and in the presence of SPIONs at low magnetic field strengths

Nicholas Bryden iD, Sebastian W Atalla, Michele Kelley, Leah R Holmes, Rosa T Branca

Magnetic Resonance in Medicine · 2023

DOI: 10.1002/mrm.29619 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2023. Written by Nicholas Bryden and 4 co-authors. Institution: Department of Physics and Astronomy, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA. Major MEDLINE topics: Xenon, Magnetic Iron Oxide Nanoparticles. Cited 3 times so far (Crossref); 61 references. The full text is freely available in PubMed Central. Funded by: NIBIB NIH HHS, NIDDK NIH HHS, National Institute of Biomedical Imaging and Bioengineering.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

To compare the effect of superparamagnetic iron oxide nanoparticles (SPIONs) on the T 1 of 129 Xe and 1 H and to measure the relaxation of 129 Xe in blood at low and high magnetic field strengths.

Methods

129 Xe and 1 H T 1 relaxometry was performed at low‐ and high‐field strengths in samples containing different SPION concentrations, while imaging was used to compare the contrast obtainable in these two field regimes. In vivo experiments at variable field strengths were performed to determine the depolarization of 129 Xe in blood and the feasibility of in vivo dissolved‐phase spectroscopy and imaging at low field.

Results

The SPION relaxivity was substantially greater at low field for 1 H, increasing from 0.92 ± 0.06 mM s −1 at 11.7T to 31.5 ± 1.8 mM s −1 at 0.6 mT, and for 129 Xe, which increased from 0.13 ± 0.03 mM s −1 at 11.7T to 7.32 ± 0.71 mM s −1 at 2.1 mT. The additional MR signal loss increased from 0.7% at 9.4T to 20.6 ± 4.2% at 0.6 mT for 1 H and from −0.7 ± 3.4% at 9.4T to 12.7 ± 3.5% at 2.1 mT for 129 Xe. Blood was found to depolarize 129 Xe below 3T in a manner inversely proportional to the field strength. In vitro studies at 2.1 mT suggest 129 Xe relaxation times below 5 s in blood dilutions as low as 0.4% volume.

Conclusion

SPIONs longitudinal relaxivity increases at low field both for 1 H and 129 Xe. The depolarization of xenon in blood, which is found to increase below 3T, effectively prevents in vivo dissolved‐phase spectroscopy and imaging at low‐field strengths.

Subjects

MeSH terms (MEDLINE)

XenonMagnetic Iron Oxide NanoparticlesMagnetic FieldsMagnetic Resonance ImagingXenon Isotopes

Author keywords

SPIONT1dissolved-phasehyperpolarized xenonlow-field MRI

Substances

XenonXenon Isotopes

Authors and institutions

  • Department of Physics and Astronomy, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA.
  • Biomedical Research Imaging Center, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA.

ORCID profiles: Nicholas Bryden

Funding

  • NIBIB NIH HHS
  • NIDDK NIH HHS
  • National Institute of Biomedical Imaging and Bioengineering
  • National Institute of Diabetes and Digestive and Kidney Diseases
  • National Science Foundation of Sri Lanka

Cite

APA

Bryden, N., Atalla, S. W., Kelley, M., Holmes, L. R., & Branca, R. T. (2023). Enhanced 129 Xe T 1 relaxation in whole blood and in the presence of SPIONs at low magnetic field strengths. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29619

Vancouver

Bryden N, Atalla SW, Kelley M, Holmes LR, Branca RT. Enhanced 129 Xe T 1 relaxation in whole blood and in the presence of SPIONs at low magnetic field strengths. Magnetic Resonance in Medicine. 2023. doi:10.1002/mrm.29619

BibTeX
@article{Bryden2023,
  author = {Bryden, Nicholas and Atalla, Sebastian W and Kelley, Michele and Holmes, Leah R and Branca, Rosa T},
  title = {Enhanced 129 Xe T 1 relaxation in whole blood and in the presence of SPIONs at low magnetic field strengths},
  journal = {Magnetic Resonance in Medicine},
  year = {2023},
  doi = {10.1002/mrm.29619}
}
Start for free →