Rapid high‐fidelity T2* mapping using single‐shot overlapping‐echo acquisition and deep learning reconstruction
Magnetic Resonance in Medicine · 2023-06 · 89 (6) · 2157-2170
DOI: 10.1002/mrm.29585 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 19.01.2023. Verfasst von Qinqin Yang und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronic Science, Xiamen University, Xiamen, Fujian, China. Hauptthemen laut MEDLINE: Deep Learning. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Purpose
To develop and evaluate a single‐shot quantitative MRI technique called GRE‐MOLED (gradient‐echo multiple overlapping‐echo detachment) for rapid mapping.
Methods
In GRE‐MOLED, multiple echoes with different TEs are generated and captured in a single shot of the k‐space through MOLED encoding and EPI readout. A deep neural network, trained by synthetic data, was employed for end‐to‐end parametric mapping from overlapping‐echo signals. GRE‐MOLED uses pure GRE acquisition with a single echo train to deliver maps less than 90 ms per slice. The self‐registered B 0 information modulated in image phase was utilized for distortion‐corrected parametric mapping. The proposed method was evaluated in phantoms, healthy volunteers, and task‐based FMRI experiments.
Results
The quantitative results of GRE‐MOLED mapping demonstrated good agreement with those obtained from the multi‐echo GRE method (Pearson's correlation coefficient = 0.991 and 0.973 for phantom and in vivo brains, respectively). High intrasubject repeatability (coefficient of variation
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electronic Science, Xiamen University, Xiamen, Fujian, China.
- The Center for Brain Imaging Science and Technology, College of Biomedical Engineering and Instrumental Science, Zhejiang University, Hangzhou, Zhejiang, China.
- Department of Magnetic Resonance Imaging, The First Affiliated Hospital of Zhengzhou University, Zhengzhou University, Zhengzhou, Henan, China.
- Department of Imaging Sciences, University of Rochester, Rochester, New York, USA.
ORCID-Profile: Qinqin Yang
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Yang, Q., Ma, L., Zhou, Z., Bao, J., Yang, Q., Huang, H., Cai, S., He, H., Chen, Z., Zhong, J., & Cai, C. (2023). Rapid high‐fidelity T2* mapping using single‐shot overlapping‐echo acquisition and deep learning reconstruction. Magnetic Resonance in Medicine, 89(6), 2157-2170. https://doi.org/10.1002/mrm.29585
Vancouver
Yang Q, Ma L, Zhou Z, Bao J, Yang Q, Huang H, et al. Rapid high‐fidelity T2* mapping using single‐shot overlapping‐echo acquisition and deep learning reconstruction. Magnetic Resonance in Medicine. 2023;89(6):2157-2170. doi:10.1002/mrm.29585
BibTeX
@article{Yang2023,
author = {Yang, Qinqin and Ma, Lingceng and Zhou, Zihan and Bao, Jianfeng and Yang, Qizhi and Huang, Haitao and Cai, Shuhui and He, Hongjian and Chen, Zhong and Zhong, Jianhui and Cai, Congbo},
title = {Rapid high‐fidelity T2* mapping using single‐shot overlapping‐echo acquisition and deep learning reconstruction},
journal = {Magnetic Resonance in Medicine},
year = {2023},
volume = {89},
number = {6},
pages = {2157--2170},
doi = {10.1002/mrm.29585}
}