EUVIMEDObjevte EUVIMED
Open access · CC BY 4.0

Magnetically enhanced peak‐to‐valley dose ratio for megavoltage photon minibeam radiotherapy

Annalisa Walpen, Werner Volken, Chengchen Zhu, Peter Manser, Michael K. Fix, Florian Amstutz

Medical Physics · 2026-12 · 53 (12)

DOI: 10.1002/mp.70763 ↗

At a glance

Journal article in Medical Physics, published online on 2026-11-19. Written by Annalisa Walpen and 5 co-authors. 30 references. The full text is freely available (open access, CC BY 4.0). Funded by: Swiss Cancer Research Foundation.

AbstraktBibliografické údajeCiteRelated studies

Abstract (original language)

Background

Orthovoltage minibeam radiotherapy (MBRT) emerged as a promising strategy to reduce normal tissue toxicities while providing equivalent or superior tumor control compared to homogeneous target irradiation. These benefits arise from the sub‐millimetric beam sizes and the highly heterogeneous dose distributions, typical for this technique. For MBRT operating at megavoltage (MV) photon energies, the lateral scattering of secondary electrons into the low dose regions poses a major limitation, compromising the therapeutic benefits observed in orthovoltage MBRT. Meanwhile, in presence of an inline magnetic field (IMF), parallel to the central axis of the incoming radiation beam, laterally scattered secondary electrons are forced onto helical trajectories around the magnetic field, thus being radially confined.

Purpose

Investigate in‐silico the effects of homogeneous IMFs with constant field strengths up to 15 T on MV‐photon minibeams, with a view to confining secondary electrons radially and thus enhancing the peak‐to‐valley dose ratio (PVDR) compared to the case where no IMF is applied.

Methods

Monte Carlo simulations were performed using a simplified minibeam beam model. A digital water phantom (10 cm x 10 cm x 15 cm) was employed. The feasibility of four different minibeam geometries with respect to the PVDR enhancement at 14 cm depth in water with IMFs (0, 1.5 and 7 T) was investigated with mono‐energetic (4, 10 and 18 MeV) photon minibeams. Out of the four geometries, the one for which the application of IMFs resulted in the most pronounced PVDR enhancement at 14 cm depth, was selected for the subsequent investigations. Using this geometry, the effects of IMFs up to 15 T on the PVDRs as a function of depth in water, were investigated for mono‐energetic (2.5, 4, 6, 10, 15 and 18 MeV) photon minibeams and for a flattened (FF) Varian TrueBeam 6 MV photon energy spectrum. Finally, PVDR enhancement was investigated in a clinically motivated brain cancer case using the TrueBeam 6 MV FF photon energy spectrum with IMFs up to 15 T.

Results

Out of the four investigated geometries, the most pronounced PVDR enhancement at 14 cm depth in water was observed using the geometry with 1.0 mm beamlet width, 5.0 mm center‐to‐center spacing combined with 4 MeV beam energy and a 7 T IMF, increasing the PVDR from 2.6 ± 0.1 at 0 T to 16.0 ± 0.8 at 7 T. With this geometry, PVDRs enhancements occurred along the entire phantom for all investigated energies. At 14 cm depth in water the PVDRs were increased across the investigated beam energies by values between 10.4 ± 0.6 and 44.9 ± 3.7, when applying IMFs of 15 T compared to 0 T. The extent to which an IMF enhanced the PVDR was found to be dependent on the IMF strength, beam energy and depth in water. In the clinically motivated brain cancer case, a magnetic field of 6 T maintained a PVDR above 10 throughout the patient's head.

Conclusion

The confinement of secondary electrons is possible with IMFs, therefore enhancing the PVDR for MV‐photon minibeams.

Funding

  • Swiss Cancer Research Foundation

Cite

APA

Walpen, A., Volken, W., Zhu, C., Manser, P., Fix, M. K., & Amstutz, F. (2026). Magnetically enhanced peak‐to‐valley dose ratio for megavoltage photon minibeam radiotherapy. Medical Physics, 53(12). https://doi.org/10.1002/mp.70763

Vancouver

Walpen A, Volken W, Zhu C, Manser P, Fix MK, Amstutz F. Magnetically enhanced peak‐to‐valley dose ratio for megavoltage photon minibeam radiotherapy. Medical Physics. 2026;53(12). doi:10.1002/mp.70763

BibTeX
@article{Walpen2026,
  author = {Walpen, Annalisa and Volken, Werner and Zhu, Chengchen and Manser, Peter and Fix, Michael K. and Amstutz, Florian},
  title = {Magnetically enhanced peak‐to‐valley dose ratio for megavoltage photon minibeam radiotherapy},
  journal = {Medical Physics},
  year = {2026},
  volume = {53},
  number = {12},
  doi = {10.1002/mp.70763}
}
Start for free →