Spectrometric characterization of x‐ray attenuation in silicone‐gel and saline breast implants under mammography and CT conditions
Medical Physics · 2026-11 · 53 (11)
DOI: 10.1002/mp.70750 ↗At a glance
Journal article in Medical Physics, published online on 2026-11-11. Written by Jérémie Lefèvre and 7 co-authors. Institution: Laboratoire National Henri Becquerel (LNE-LNHB), Université Paris-Saclay, CEA, List, Palaiseau, France. Major MEDLINE topics: Breast Implants, Tomography, X-Ray Computed, Mammography, Silicone Gels. 45 references. Funded by: Commissariat à l'Énergie Atomique et aux Énergies Alternatives.
Abstract (original language)
Background
Breast implants alter x‐ray beam attenuation, but quantitative energy‐resolved data for commercial prostheses are largely missing from the literature. Current dosimetric protocols lack specific correction factors for implant materials.
Purpose
To measure the x‐ray attenuation properties of silicone‐gel (PDMS) and saline breast implants under mammography and computed tomography (CT) conditions.
Methods
We performed transmission spectrometry on six breast implants (three PDMS, three saline‐filled) from a single manufacturer, using a cadmium telluride (CdTe) detector in narrow‐beam geometry. Energy‐dependent linear attenuation coefficients, effective attenuation coefficients (), half‐value layers, and bulk densities were determined for mammography (25–49 kV) and CT (80–120 kV) beam qualities. Combined uncertainties were 3%–5%.
Results
Under mammographic conditions, PDMS attenuates more than saline: values are roughly 1.5–2 times higher, because of enhanced photoelectric absorption linked to a higher effective atomic number ( vs. 7.5). Saline implants behave much like water and soft breast tissues. The monoenergetic attenuation curves of the two materials converge above 60 keV as Compton scattering comes to dominate, but the spectrum‐weighted effective attenuation still differs by 40% at a representative 80 kV Al CT tube potential (0.48 vs. 0.34 ), narrowing to 10% only with harder filtration and higher tube potential combined (120 kV AlCu). We provide log–log polynomial fits suitable for dosimetric codes.
Conclusions
These measurements supply energy‐resolved attenuation data for silicone‐gel and saline implants across the diagnostic range. PDMS and saline differ substantially at mammographic energies. Their monoenergetic attenuation converges in the Compton regime, but spectrum‐weighted differences persist at 80 kV and should be accounted for in breast CT dosimetry. The results are consistent with recent phantom findings on AEC response and dose variations in the presence of silicone implants.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Laboratoire National Henri Becquerel (LNE-LNHB), Université Paris-Saclay, CEA, List, Palaiseau, France.
- Department of Radiology, AP-HP, Hôpital Européen Georges Pompidou, Paris, France.
Funding
- Commissariat à l'Énergie Atomique et aux Énergies Alternatives
Cite
APA
Lefèvre, J., Kerfa, J., Bony, M., Plagnard, J., Catheline, M., Fitton, I., Ty, C. V. N., & Bordy, J. M. (2026). Spectrometric characterization of x‐ray attenuation in silicone‐gel and saline breast implants under mammography and CT conditions. Medical Physics, 53(11). https://doi.org/10.1002/mp.70750
Vancouver
Lefèvre J, Kerfa J, Bony M, Plagnard J, Catheline M, Fitton I, et al. Spectrometric characterization of x‐ray attenuation in silicone‐gel and saline breast implants under mammography and CT conditions. Medical Physics. 2026;53(11). doi:10.1002/mp.70750
BibTeX
@article{Lefvre2026,
author = {Lefèvre, Jérémie and Kerfa, Jade and Bony, Mathis and Plagnard, Johann and Catheline, Marion and Fitton, Isabelle and Ty, Claire Von Ngoc and Bordy, Jean-Marc},
title = {Spectrometric characterization of x‐ray attenuation in silicone‐gel and saline breast implants under mammography and CT conditions},
journal = {Medical Physics},
year = {2026},
volume = {53},
number = {11},
doi = {10.1002/mp.70750}
}
EUVIMED