EUVIMEDDescubrir EUVIMED
Crossref

A novel image‐domain denoising method for triple‐material decomposition in dual‐energy CT

Jiexiong Wu, Xiaogang Yuan, Yidong Yang

Medical Physics · 2026-11 · 53 (11)

DOI: 10.1002/mp.70723 ↗

At a glance

Journal article in Medical Physics, published online on 2026-11-14. Written by Jiexiong Wu and 2 co-authors. Institution: Department of Engineering and Applied Physics, University of Science and Technology of China, Hefei, Anhui, People's Republic of China. Major MEDLINE topics: Tomography, X-Ray Computed, Image Processing, Computer-Assisted, Signal-To-Noise Ratio. 42 references. Funded by: Ministry of Science and Technology of China Key Research and Development Projects, Fundamental Research Funds for the Central Universities, Hefei Comprehensive National Science Center.

ResumenSubjectsDatos bibliográficosCiteRelated studies

Abstract (original language)

Background

Triple‐material decomposition (TMD) holds significant clinical value in dual‐energy computed tomography (DECT), as it enables simultaneous differentiation of bone, soft tissue, and contrast agents—three key components commonly targeted in clinical imaging assessments. However, the inherent noise amplification artifact associated with material decomposition remains a critical technical bottleneck that restricts its widespread clinical translation.

Purpose

To address this limitation, this study proposes an image‐domain denoising strategy to mitigate noise amplification, thereby improving the quantitative accuracy and qualitative quality of TMD in DECT.

Method

First, DECT images were transformed into amplitude and argument components via vectorization. Second, a spectral joint bilateral filtering algorithm was developed to specifically denoise the argument images, leveraging inter‐spectral correlation to preserve structural details while suppressing noise. Subsequently, denoised DECT images were reconstructed using the original amplitude and denoised argument components. TMD was performed with soft tissue, bone, and contrast agent as basis materials, utilizing two decomposition approaches: direct matrix inversion (DMI) and the penalized weighted least squares‐expectation maximization‐loop (PWLS‐EP‐LOOP) iterative method. The proposed denoising strategy was validated on a benchtop micro‐CT system, with evaluations conducted on both a customized anthropomorphic phantom and an in vivo mouse model injected with ExiTron nano 6000 contrast agent.

Results

For DMI‐based decomposition, the proposed method achieved noise reduction rates (NRRs) of 68.9% in soft tissue images, 74.4% in contrast‐enhanced images, and 78.7% in bone images. For PWLS‐EP‐LOOP‐based iterative decomposition, the corresponding NRRs were 22.4% (soft tissue), 48.6% (contrast agent), and 37.5% (bone). Furthermore, the number of iteration cycles required for convergence in the PWLS‐EP‐LOOP algorithm was reduced by 75.4%, substantially improving computational efficiency.

Conclusion

Experimental results demonstrate that the proposed image‐domain denoising method, tailored for DECT TMD, effectively suppresses noise in both DMI and iterative workflows while preserving structural fidelity. This work thus provides a promising solution to enhance the clinical utility of DECT material decomposition.

Subjects

MeSH terms (MEDLINE)

Tomography, X-Ray ComputedImage Processing, Computer-AssistedSignal-To-Noise RatioAnimalsMicePhantoms, ImagingAlgorithms

Author keywords

denoisingdual‐energy CTtriple‐material decomposition

Authors and institutions

  • Department of Engineering and Applied Physics, University of Science and Technology of China, Hefei, Anhui, People's Republic of China.
  • Department of Radiation Oncology, Division of Life Sciences and Medicine, the First Affiliated Hospital of USTC, University of Science and Technology of China, Hefei, Anhui, People's Republic of China.
  • Ion Medical Research Institute, University of Science and Technology of China, Hefei, Anhui, People's Republic of China.

Funding

  • Ministry of Science and Technology of China Key Research and Development Projects
  • Fundamental Research Funds for the Central Universities
  • Hefei Comprehensive National Science Center

Cite

APA

Wu, J., Yuan, X., & Yang, Y. (2026). A novel image‐domain denoising method for triple‐material decomposition in dual‐energy CT. Medical Physics, 53(11). https://doi.org/10.1002/mp.70723

Vancouver

Wu J, Yuan X, Yang Y. A novel image‐domain denoising method for triple‐material decomposition in dual‐energy CT. Medical Physics. 2026;53(11). doi:10.1002/mp.70723

BibTeX
@article{Wu2026,
  author = {Wu, Jiexiong and Yuan, Xiaogang and Yang, Yidong},
  title = {A novel image‐domain denoising method for triple‐material decomposition in dual‐energy CT},
  journal = {Medical Physics},
  year = {2026},
  volume = {53},
  number = {11},
  doi = {10.1002/mp.70723}
}
Start for free →