A physics primer on photon‐counting detectors in CT: Physics, signal formation, and performance
Medical Physics · 2026-08 · 53 (8)
DOI: 10.1002/mp.70586 ↗At a glance
Übersichtsarbeit in Medical Physics, published online on 2026-07-21. Written by Guang-Hong Chen and 2 co-authors. Institution: Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA. Major MEDLINE topics: Photons, Tomography, X-Ray Computed, Physics, Physical Phenomena. Cited 1 times so far (Crossref); 146 references. The full text is freely available (open access, CC BY 4.0). Funded by: NIBIB NIH HHS, Wisconsin Alumni Research Foundation, GE Healthcare.
Abstract (original language)
Photon‐counting detector CT (PCD‐CT) is moving from laboratory development to clinical deployment. However, its threshold‐bin data arise from a tightly coupled detector–readout chain that can be difficult to understand as a whole. These data are not a direct readout of photon energy, but the outcome of a sequence of physical and electronic processes that begins with x‐ray interaction and charge creation and ends with threshold decisions applied to processed electrical pulses. Understanding this chain is essential for interpreting detector behavior, evaluating performance, and identifying the origins of spectral distortion, count loss, and instability under clinical operating conditions. This primer presents a physics‐grounded framework for semiconductor photon‐counting detectors in CT by organizing the discussion around a single causal chain: energy deposition, charge creation, charge transport, signal induction, pulse formation, and final event counting and multi‐threshold energy binning. Within this framework, we show how charge sharing, detector pixel geometry, dead time, pileup, dark current, contact‐controlled leakage, and operating conditions shape spectral response, count‐rate performance, threshold stability, and reproducibility at clinical flux. By linking detector physics, waveform formation, threshold logic, contact physics, operating conditions, and practical performance characterization within one coherent framework, this primer aims to give medical physicists and imaging researchers a scientifically rigorous and operationally useful understanding of how photon‐counting CT detectors work and what governs their performance.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Department of Imaging Physics, University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
- Department of Interventional Radiology, University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
Funding
- NIBIB NIH HHS
- Wisconsin Alumni Research Foundation
- GE Healthcare
- NIH HHS
- National Institutes of Health
Cite
APA
Chen, G. H., Lai, R., & Li, K. (2026). A physics primer on photon‐counting detectors in CT: Physics, signal formation, and performance. Medical Physics, 53(8). https://doi.org/10.1002/mp.70586
Vancouver
Chen GH, Lai R, Li K. A physics primer on photon‐counting detectors in CT: Physics, signal formation, and performance. Medical Physics. 2026;53(8). doi:10.1002/mp.70586
BibTeX
@article{Chen2026,
author = {Chen, Guang-Hong and Lai, Ruiran and Li, Ke},
title = {A physics primer on photon‐counting detectors in CT: Physics, signal formation, and performance},
journal = {Medical Physics},
year = {2026},
volume = {53},
number = {8},
doi = {10.1002/mp.70586}
}