EUVIMEDDescoperă EUVIMED
Open access

TOPAS‐nBio simulation of the impact of ultrahigh dose rate and oxygen concentration on the Fenton reaction using the Fricke solution

TOPAS‐nBio-Simulation des Einflusses von ultrahoher Dosisrate und Sauerstoffkonzentration auf die Fenton-Reaktion mit der Fricke-Lösung

M Chaoui, W G Shin, O Bouhali, J Schuemann, J Ramos-Méndez, Y Tayalati

Medical Physics · 2026-08 · 53 (8)

DOI: 10.1002/mp.70576 ↗

Auf einen Blick

Die Simulation zeigt unter ultrahoher Dosisrate eine geringere Aktivierung der Fenton-Reaktion als unter konventioneller Dosisrate. Der Effekt war bei niedriger Anfangs-Sauerstoffkonzentration am stärksten.

Fragestellung

Wie beeinflussen Pulsbreite, Dosis, Dosisrate und Anfangs-Sauerstoffkonzentration die Aktivierung der Fenton-Reaktion in der Fricke-Lösung?

Methode

TOPAS-nBio-Simulation der Radiolyse einer Fricke-Lösung in einem 3 µm großen Wasserphantom mit 300 MeV Protonen; Vergleich von UHDR- und konventionellen Bestrahlungsbedingungen.

Ergebnisse

Unter CONV stimmte G(Fe3+) mit ICRU-34-Daten innerhalb (0,97 ± 0,1) % überein. Bei UHDR reduzierte 10 Gy die Fenton-Reaktionen um 1 % bei 21 % pO2 und um 11,5 % bei 1 % pO2; G(Fe3+) sank um 1,8 % bzw. 12,5 %. Bei 40 Gy sank G(Fe3+) bei 1 % pO2 um 40 %.

Schlussfolgerung der Autor:innen

Die Autoren schreiben, dass die Abnahme von G(Fe3+) vor allem durch Intertrack-Effekte bedingt ist, die unter UHDR-Bedingungen Radikale für die Fenton-Chemie begrenzen. Der Effekt ist bei niedriger Anfangs-Sauerstoffkonzentration am stärksten.

Kernaussagen

  • UHDR senkte die Fenton-Reaktion gegenüber CONV
  • Stärkster Effekt bei 1 % pO2
  • Lange Pulse und 0,28 Gy/s machten den Effekt nahezu bedeutungslos

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

At a glance

Journal article in Medical Physics, published online on 2026-08-06. Written by M Chaoui and 5 co-authors. Institution: Faculty of Sciences, University Mohammed V in Rabat, Rabat, Morocco. Major MEDLINE topics: Oxygen, Hydrogen Peroxide, Iron, Radiation Dosage. 77 references. The full text is freely available in PubMed Central. Funded by: OCP Foundation, NIH/NCI, NCI NIH HHS.

Auf einen BlickRezumatSubjectsDate bibliograficeCiteRelated studies

Abstract (original language)

Background

Preclinical studies have shown that FLASH radiotherapy (FLASH‐RT), delivering radiation in ultrahigh dose rates (UHDR), presents reduced healthy tissue toxicity, while maintaining an iso‐effective tumor response compared to conventional radiotherapy (CONV‐RT). This combined biological benefit was termed as “FLASH effect.” The mechanisms responsible for this effect remain unclear, however, it has been hypothesized that the Fenton reaction which produces can inflict substantial damage to biomolecules and thus might play a role in the “FLASH effect.” Purpose We propose to investigate the influence of radiation delivery parameters including pulse width, dose, dose rate, and initial oxygen concentration on the activation of the Fenton reaction using the Fricke solution. Methods and materials TOPAS‐nBio version 4.0 was used to simulate the radiolysis of the Fricke solution. A cubic water phantom (3 µm side) was irradiated laterally by 300 MeV protons. Irradiation was delivered in pulses of tracks with absorbed doses from 1–40 Gy, or in independent tracks. For ultrahigh dose rate (UHDR), we varied the pulse widths between 10 ns and 10 µs, corresponding to instantaneous dose rates of 10 9 –10 5 Gy/s. For conventional dose rate (CONV), both the independent history approach (mimicking 6 0 Co) and multi‐pulse irradiations at different frequencies were simulated, yielding a mean dose rate of 0.28 Gy/s. Irradiation times reached between 78 ns‐85 s. Oxygen concentrations in the equivalent condition of hypoxic and normoxic tissues (1%‐21%) were considered. The G ‐value for oxidant ions G(Fe 3+ ) and Δ G ‐value of Fenton reaction (H 2 O 2 + Fe 2+ → Fe 3+ ++ ) were scored. The simulations ended after G(Fe 3+ ) achieved steady‐state, and calculated yields were compared with published data.

Results

For CONV, G(Fe 3+ ) agreed with ICRU‐report 34 data within (0.97 ± 0.1)%. For UHDR, G(Fe 3+ ) agreed with ICRU data within (1.24 ± 0.1) % and (0.92 ± 0.1) % for 5 and 10 Gy, respectively. Notably, UHDR at 10 Gy reduced the occurrence of Fenton reactions by 1% and 11.5% at initial oxygen of 21% pO 2 and 1% pO 2 , respectively. In consequence, UHDR decreased G(Fe 3+ ) by 1.8% and 12.5% at these oxygen levels. Additionally, increasing the dose per pulse to 40 Gy further reduced the G(Fe 3+ ) by 40% at 1%pO 2 . This effect became negligible for long pulse durations ≥10 µs and low mean dose rate (0.28 Gy/s), highlighting the importance of instantaneous dose rates. Precisely, the decrease was driven by intertrack effects present in UHDR pulses and their impact on the scavenging effect that oxygen had over hydrogen radicals.

Conclusions

The observed reduction in G(Fe 3 + ) is primarily driven by inter‐track effects, which limit the availability of radicals participating in Fenton chemistry under UHDR conditions. This effect is most pronounced at low initial oxygen concentrations and minimal at higher oxygen concentrations. The effect is further amplified at higher per‐pulse doses (25–40 Gy) but vanishes at long pulse durations and low mean dose rates. This emphasizes the important role of the initial oxygen concentration in UHDR and its influence on the latest activation of Fenton reaction, a mechanism that may contribute to elucidating the FLASH effect.

Subjects

MeSH terms (MEDLINE)

OxygenHydrogen PeroxideIronRadiation DosageRadiotherapy DosageSolutions

Author keywords

Fricke solutionUHDRfenton reactionflash radiotherapyoxygen

Substances

OxygenHydrogen PeroxideIronFenton's reagentSolutions

Authors and institutions

  • Faculty of Sciences, University Mohammed V in Rabat, Rabat, Morocco.
  • Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, USA.
  • Electrical Engineering, College of Science and Engineering, Hamad Bin Khalifa University, Doha, Qatar.
  • Department of Radiation Oncology, University of California, San Francisco, California, USA.
  • College of Physical Sciences and Engineering, Mohammed VI Polytechnic University, Ben Guerir, Morocco.

Funding

  • OCP Foundation
  • NIH/NCI
  • NCI NIH HHS
  • Moroccan Ministry of Higher Education, Scientific Research and Innovation

Cite

APA

Chaoui, M., Shin, W. G., Bouhali, O., Schuemann, J., Ramos-Méndez, J., & Tayalati, Y. (2026). TOPAS‐nBio simulation of the impact of ultrahigh dose rate and oxygen concentration on the Fenton reaction using the Fricke solution. Medical Physics, 53(8). https://doi.org/10.1002/mp.70576

Vancouver

Chaoui M, Shin WG, Bouhali O, Schuemann J, Ramos-Méndez J, Tayalati Y. TOPAS‐nBio simulation of the impact of ultrahigh dose rate and oxygen concentration on the Fenton reaction using the Fricke solution. Medical Physics. 2026;53(8). doi:10.1002/mp.70576

BibTeX
@article{Chaoui2026,
  author = {Chaoui, M and Shin, W G and Bouhali, O and Schuemann, J and Ramos-Méndez, J and Tayalati, Y},
  title = {TOPAS‐nBio simulation of the impact of ultrahigh dose rate and oxygen concentration on the Fenton reaction using the Fricke solution},
  journal = {Medical Physics},
  year = {2026},
  volume = {53},
  number = {8},
  doi = {10.1002/mp.70576}
}
Start for free →