EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A projection‐domain deep learning approach for respiratory motion correction of myocardial perfusion imaging using a multi‐pinhole solid‐state SPECT

Dylan J Malenfant, Terrence D Ruddy, R Glenn Wells

Medical Physics · 2026-08 · 53 (8)

DOI: 10.1002/mp.70543 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, online erschienen am 22.07.2026. Verfasst von Dylan J Malenfant und 2 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Department of Medicine, University of Ottawa Heart Institute, Ottawa, Ontario, Canada. Hauptthemen laut MEDLINE: Myocardial Perfusion Imaging, Tomography, Emission-Computed, Single-Photon, Image Processing, Computer-Assisted, Deep Learning. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Ottawa Heart Institute, NSERC, Natural Sciences and Engineering Research Council of Canada.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Myocardial perfusion imagining (MPI) is a nuclear medicine technique used in the assessment of coronary artery disease. Differences in the perfusion of the myocardium at rest and stress and regions of perfusion defects can be indicators of various cardiac disease states. Respiratory motion (RM) can result in the degradation of image quality and the appearance of artificial regions of perfusion deficit. While RM correction is possible, many methods involve time‐consuming calculation or additional equipment for motion tracking. This has limited the clinical uptake of such methods. This work presents a deep learning model for data‐driven RM correction on dedicated cardiac SPECT scanners.

Purpose

An AI‐based method for estimating RM from gated projection data for MPI SPECT using a dedicated pinhole scanner was developed. Accuracy of these estimates and impact on image characteristics were assessed.

Methods

RM motion parameters were calculated for rest and stress MPI scans using a minimized root mean squared (RMS) alignment of reconstructed respiratory gates for 90 patients supplemented with 33 NCAT simulated patients. Using these parameters, an AI network was trained to estimate motion based on gated projection data prior to reconstruction. Accuracy of AI predictions relative to RMS data were assessed for clinical scans and down‐sampled data to simulate noisy acquisitions. Scans were reconstructed with AI motion correction (MC), RMS MC, and no MC. Anterior myocardial wall thickness and its contrast relative to the interior of the ventricle were calculated in each case.

Results

AI motion predictions were accurate to within 1.86 ± 0.05 mm at clinical noise levels, increasing to 2.07 ± 0.07 mm at 1/8 signal. MC with AI was shown to provide a statistically significant increase anterior wall contrast and decrease measured wall thickness relative to no MC, with comparable results to RMS MC.

Conclusion

Direct AI‐based MC parameter estimation using gated projection data was shown to be feasible in clinical settings. Corrections based on AI estimates showed improved contrast and reduced myocardial wall thickness when incorporated into image reconstruction.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Myocardial Perfusion ImagingTomography, Emission-Computed, Single-PhotonImage Processing, Computer-AssistedDeep LearningRespirationMovementHumans

Stichwörter der Autor:innen

cardiac SPECTdeep learningrespiratory motion

Autor:innen und Institutionen

  • Division of Cardiology, Department of Medicine, University of Ottawa Heart Institute, Ottawa, Ontario, Canada.
  • Department of Physics, Carleton University, Ottawa, Ontario, Canada.

Förderung

  • University of Ottawa Heart Institute
  • NSERC
  • Natural Sciences and Engineering Research Council of Canada

Zitieren

APA

Malenfant, D. J., Ruddy, T. D., & Wells, R. G. (2026). A projection‐domain deep learning approach for respiratory motion correction of myocardial perfusion imaging using a multi‐pinhole solid‐state SPECT. Medical Physics, 53(8). https://doi.org/10.1002/mp.70543

Vancouver

Malenfant DJ, Ruddy TD, Wells RG. A projection‐domain deep learning approach for respiratory motion correction of myocardial perfusion imaging using a multi‐pinhole solid‐state SPECT. Medical Physics. 2026;53(8). doi:10.1002/mp.70543

BibTeX
@article{Malenfant2026,
  author = {Malenfant, Dylan J and Ruddy, Terrence D and Wells, R Glenn},
  title = {A projection‐domain deep learning approach for respiratory motion correction of myocardial perfusion imaging using a multi‐pinhole solid‐state SPECT},
  journal = {Medical Physics},
  year = {2026},
  volume = {53},
  number = {8},
  doi = {10.1002/mp.70543}
}
Kostenlos starten →