Magnetic resonance imaging‐guided large‐scale lesion patterning with high‐intensity focused ultrasound in homogeneous phantoms
Medical Physics · 2026
DOI: 10.1002/mp.70503 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, 2026. Verfasst von Anastasia Antoniou und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus. Hauptthemen laut MEDLINE: Phantoms, Imaging, High-Intensity Focused Ultrasound Ablation, Magnetic Resonance Imaging, Surgery, Computer-Assisted. Die Arbeit nennt 24 Literaturangaben. Gefördert von: Research and Innovation Foundation (RIF) of Cyprus.
Abstract (Originalsprache)
Background
In typical high‐intensity focused ultrasound (HIFU) therapy, energy is delivered sequentially to multiple focal points to collectively shape the overall treatment zone. However, the behavior of large‐scale grid sonication patterns in homogeneous media under magnetic resonance imaging (MRI) guidance has not been fully characterized.
Purpose
To characterize the spatial fidelity and MRI appearance of large‐scale HIFU sonication grids in an agar‐silica tissue‐mimicking phantom and to describe their observed behavior relative to biological tissue.
Methods
Rectangular and irregular large‐scale (∼100‐point) grids were executed in agar‐silica phantoms using an MRI‐guided HIFU robotic system with a single‐element transducer under 3T MRI guidance. T2‐weighted (T2‐w) Turbo Spin Echo (TSE) images were acquired after each sonication row for lesion monitoring and post‐sonication quantification. Each grid configuration was evaluated in a separate phantom preparation. Descriptive metrics were used to characterize lesion morphology and spatial fidelity, quantified using lesion diameter and Euclidean localization error when individual lesions were distinguishable, and region‐level descriptors (area and centroid position) for merged lesion regions. One of the grid protocols was also applied to freshly excised porcine skeletal muscle, with lesion formation monitored using the same MRI‐based approach.
Results
In the phantom, lesions appeared as hyperintense regions at the intended focal depth and closely reproduced the prescribed grid geometry. For a standardized 10 × 10 grid (4 mm spacing) in the ablative regime, individual lesions exhibited a mean diameter of 3.0 ± 0.7 mm and a mean Euclidean localization error of ∼2.5 ± 0.7 mm relative to the planned coordinates. When inter‐point spacing approached the lesion diameter, adjacent sonications produced merged regions that preserved the overall grid footprint while forming contiguous thermal coverage. In the irregular configuration, grid coverage was 96%, with a centroid offset of ∼1 mm. Under the tested conditions, ex vivo porcine muscle exhibited incomplete lesion formation and a shift of ∼15 mm from the prescribed depth, producing an irregular hypointense region displaced toward the tissue surface.
Conclusions
This study documented the successful generation and MRI visualization of large‐scale HIFU grid patterns in an agar‐silica phantom using T2‐w imaging. Under the tested conditions, the observed hyperintense regions showed spatial correspondence with the prescribed grid geometry. Observations in freshly excised porcine skeletal muscle recorded variations in lesion formation in the presence of biological heterogeneity, while the agar‐silica phantom provided a standardized platform for system‐level testing as configured in this study.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus.
- Diagnostic and Interventional Radiology Department, German Medical Institute, Limassol, Cyprus.
- Department of Electronics and Information Engineering, Hangzhou Dianzi University, Hangzhou, Zhejiang, China.
- 3DMI Research Group, Department of Medical Physics, School of Medicine, University of Patras, Patras, Greece.
Förderung
- Research and Innovation Foundation (RIF) of Cyprus
Zitieren
APA
Antoniou, A., Evripidou, N., Georgiou, L., Christofi, A., Zhao, J., Yu, L., Li, W., Kagadis, G. C., & Damianou, C. (2026). Magnetic resonance imaging‐guided large‐scale lesion patterning with high‐intensity focused ultrasound in homogeneous phantoms. Medical Physics. https://doi.org/10.1002/mp.70503
Vancouver
Antoniou A, Evripidou N, Georgiou L, Christofi A, Zhao J, Yu L, et al. Magnetic resonance imaging‐guided large‐scale lesion patterning with high‐intensity focused ultrasound in homogeneous phantoms. Medical Physics. 2026. doi:10.1002/mp.70503
BibTeX
@article{Antoniou2026,
author = {Antoniou, Anastasia and Evripidou, Nikolas and Georgiou, Leonidas and Christofi, Antonis and Zhao, Jufeng and Yu, Liyang and Li, Wenjun and Kagadis, George C and Damianou, Christakis},
title = {Magnetic resonance imaging‐guided large‐scale lesion patterning with high‐intensity focused ultrasound in homogeneous phantoms},
journal = {Medical Physics},
year = {2026},
doi = {10.1002/mp.70503}
}
EUVIMED