EUVIMEDDescubrir EUVIMED
Crossref

An Interpretable Radiomics Model Based on Multi‐DLCT Images for Differentiating Benign and Malignant Solid Solitary Pulmonary Nodules

Ze Lin, Pei Huang, Shiyin Xiao, Bing Fan, Yiqing Tan, Shiyong Luo, Yu Wang, Xiao Yu, Danmei Zhang, Minjing Zuo

Medical Physics · 2026-04 · 53 (4)

DOI: 10.1002/mp.70443 ↗

At a glance

Journal article in Medical Physics, published online on 2026-04-19. Written by Ze Lin and 9 co-authors. Institution: Department of Radiology, Wuhan Third Hospital (Tongren Hospital of WuHan University), Wuhan, China. Major MEDLINE topics: Radiomics, Solitary Pulmonary Nodule, Tomography, X-Ray Computed, Lung Neoplasms. 30 references. Funded by: National Natural Science Foundation of China, Jiangxi Provincial Department of Science and Technology.

ResumenSubjectsDatos bibliográficosCiteRelated studies

Abstract (original language)

Background

Early‐stage lung cancer frequently presents as a solitary pulmonary nodule. Compared with subsolid pulmonary nodules, solid pulmonary nodules are associated with greater invasiveness, earlier metastasis, faster growth, and worse clinical outcomes. Therefore, early diagnosis is essential for improving survival and prognosis.

Purpose

To develop an interpretable radiomics model using multi‐parametric images derived from dual‐layer CT (DLCT) for the non‐invasive differentiation of benign and malignant solid solitary pulmonary nodules (SSPNs).

Methods

This retrospective study included 236 patients with pathologically confirmed SSPNs who underwent DLCT‐enhanced scanning at two centers. Patients from one center were randomly divided into a training cohort ( n = 111) and an internal test cohort ( n = 48) at a 7:3 ratio, while patients from the other center served as an external test cohort ( n = 77). Radiomic features were independently extracted from seven venous‐phase image series, including conventional images (CI), iodine density (ID) maps, effective atomic number (Zeff) maps, electron density (ED) maps, virtual monochromatic images (VMI) at 40 and 100 keV, and virtual non‐contrast (VNC) images, and were subsequently selected using the Mann–Whitney U test, Spearman correlation analysis, and LASSO. Radiomics models based on individual image series and combined models were constructed using logistic regression, SVM, and XGBoost. Model performance was evaluated using the area under the receiver operating characteristic curve (AUC), accuracy, sensitivity, and specificity. SHapley Additive Explanations (SHAP) were applied to interpret the fusion model.

Results

The SVM‐based combined model demonstrated stable diagnostic performance across cohorts (AUC = 0.909, 0.852, and 0.793 for the training, internal test, and external test cohorts, respectively), achieving the highest AUC among all models in the external test cohort. In the external test cohort using the SVM algorithm, the combined model showed a higher AUC than the CI model (AUC = 0.793 vs. 0.667; P = 0.125), with positive NRI and IDI.

Conclusions

An interpretable radiomics model based on multi‐parametric DLCT images using the SVM algorithm enables accurate and robust noninvasive differentiation of benign and malignant SSPNs.

Subjects

MeSH terms (MEDLINE)

RadiomicsSolitary Pulmonary NoduleTomography, X-Ray ComputedLung NeoplasmsImage Processing, Computer-AssistedHumansDiagnosis, DifferentialRetrospective StudiesFemaleMaleMiddle AgedAgedROC Curve

Author keywords

diagnosis (differential)dual‐layer spectral detector CTlung cancerradiomicssolitary pulmonary nodule

Authors and institutions

  • Department of Radiology, Wuhan Third Hospital (Tongren Hospital of WuHan University), Wuhan, China.
  • Department of Radiology, Jiangxi Provincial People's Hospital, The First Affiliated Hospital of Nanchang Medical College, Nanchang, China.
  • Department of Radiology, Hubei Provincial Hospital of Traditional Chinese Medicine, Wuhan, China.
  • Clinical and Technical Support, Philips Healthcare, Jing'an District, Shanghai, China.
  • Department of Infectious Diseases, Renmin Hospital of Wuhan University, Wuhan, China.
  • Department of Radiology, The Second Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, China.

Funding

  • National Natural Science Foundation of China
  • Jiangxi Provincial Department of Science and Technology

Cite

APA

Lin, Z., Huang, P., Xiao, S., Fan, B., Tan, Y., Luo, S., Wang, Y., Yu, X., Zhang, D., & Zuo, M. (2026). An Interpretable Radiomics Model Based on Multi‐DLCT Images for Differentiating Benign and Malignant Solid Solitary Pulmonary Nodules. Medical Physics, 53(4). https://doi.org/10.1002/mp.70443

Vancouver

Lin Z, Huang P, Xiao S, Fan B, Tan Y, Luo S, et al. An Interpretable Radiomics Model Based on Multi‐DLCT Images for Differentiating Benign and Malignant Solid Solitary Pulmonary Nodules. Medical Physics. 2026;53(4). doi:10.1002/mp.70443

BibTeX
@article{Lin2026,
  author = {Lin, Ze and Huang, Pei and Xiao, Shiyin and Fan, Bing and Tan, Yiqing and Luo, Shiyong and Wang, Yu and Yu, Xiao and Zhang, Danmei and Zuo, Minjing},
  title = {An Interpretable Radiomics Model Based on Multi‐DLCT Images for Differentiating Benign and Malignant Solid Solitary Pulmonary Nodules},
  journal = {Medical Physics},
  year = {2026},
  volume = {53},
  number = {4},
  doi = {10.1002/mp.70443}
}
Start for free →