EUVIMEDDescobrir EUVIMED
Open access · CC BY-NC-ND 4.0

A simulation study of a novel spiral volumetric modulated arc therapy for enhanced dose delivery efficiency and quality in radiotherapy

Kuo Li, Wei Zhang, Xingmin Ma, Qichao Zhou, Jian Zhu

Medical Physics · 2026-04 · 53 (4)

DOI: 10.1002/mp.70423 ↗

At a glance

Journal article in Medical Physics, published online on 2026-04-03. Written by Kuo Li and 4 co-authors. Institution: Department of Radiation Oncology Physics & Technology, Cancer Hospital of Shandong First Medical University, Jinan, China. Major MEDLINE topics: Radiotherapy, Intensity-Modulated, Radiation Dosage. 39 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Key Research and Development Program of Shandong Province, Taishan Scholars Foundation of Shandong Province, Major National Science and Technology Project.

ResumoSubjectsDados bibliográficosCiteRelated studies

Abstract (original language)

Background

Conventional volumetric modulated arc therapy (VMAT) is limited by its longitudinal field size for large targets, often requiring multiple isocenters, while Helical Tomotherapy (HT) offers superior longitudinal conformity but suffers from prolonged treatment times due to its narrow fan beam.

Purpose

This simulation study proposes a novel spiral volumetric modulated arc therapy (SVMAT) technique designed to bridge this gap by synergizing continuous couch movement with dynamic MLC modulation.

Methods

The SVMAT technique was implemented on a model of ring‐gantry linac with dual‐layer staggered MLC. Its core is a direct aperture optimization algorithm that discretizes the delivery path into finite projections, concurrently optimizing MLC aperture, monitor unit weight, gantry angle, and couch position. A comprehensive dosimetric and efficiency comparison was conducted against state‐of‐the‐art VMAT and HT plans for three clinically challenging scenarios: hippocampal‐sparing whole‐brain radiotherapy (HS‐WBRT), bilateral breast radiotherapy (BBRT), and craniospinal irradiation (CSI), including a pediatric subgroup.

Results

SVMAT demonstrated comparable or superior target coverage and conformity index to VMAT and HT across all cases. Its most significant advantage was in organ‐at‐risk (OAR) sparing. For HS‐WBRT, SVMAT significantly reduced the maximum (D max ) and mean (D mean ) doses to the hippocampus compared to both VMAT and HT ( p < 0.05). For BBRT, SVMAT notably reduced the heart D mean (4.78 ± 0.86 Gy vs. 9.47 ± 3.44 Gy) for VMAT. In CSI, SVMAT reduced the lens D max by over 33% and the heart D mean by 36.1%. Also, the pediatric CSI analysis confirmed these benefits, with SVMAT significantly reducing doses to developing organs. Regarding efficiency, SVMAT's beam on time was significantly shorter than HT's across all plans (reductions of 33.1% to 55.3%) and was comparable to the multi‐isocenter VMAT in CSI.

Conclusions

The SVMAT technique successfully integrates the dynamic delivery of VMAT with the longitudinal integration and single‐isocenter capability of HT. By offering enhanced OAR sparing and reduced treatment times, SVMAT represents a significant advancement in radiotherapy, showing immense potential for improving outcomes, especially in vulnerable populations such as pediatric patients.

Subjects

MeSH terms (MEDLINE)

Radiotherapy, Intensity-ModulatedRadiation DosageRadiotherapy DosageHumansRadiotherapy Planning, Computer-AssistedOrgans at Risk

Author keywords

direct aperture optimizationdosimetric and efficiencypediatric patientsspiral volumetric modulated arc therapy

Authors and institutions

  • Department of Radiation Oncology Physics & Technology, Cancer Hospital of Shandong First Medical University, Jinan, China.
  • Manteia Technologies Co., Ltd, Xiamen, Fujian, China.
  • Centre de Recherche en Information BioMdicale Sino-français, Nanjing, China.
  • Shandong Provincial Key Medical and Health Laboratory of Pediatric Cancer Precision Radiotherapy (Shandong Cancer Hospital), Jinan, China.

Funding

  • Key Research and Development Program of Shandong Province
  • Taishan Scholars Foundation of Shandong Province
  • Major National Science and Technology Project
  • Key Technology Research and Development Program of Shandong Province

Cite

APA

Li, K., Zhang, W., Ma, X., Zhou, Q., & Zhu, J. (2026). A simulation study of a novel spiral volumetric modulated arc therapy for enhanced dose delivery efficiency and quality in radiotherapy. Medical Physics, 53(4). https://doi.org/10.1002/mp.70423

Vancouver

Li K, Zhang W, Ma X, Zhou Q, Zhu J. A simulation study of a novel spiral volumetric modulated arc therapy for enhanced dose delivery efficiency and quality in radiotherapy. Medical Physics. 2026;53(4). doi:10.1002/mp.70423

BibTeX
@article{Li2026,
  author = {Li, Kuo and Zhang, Wei and Ma, Xingmin and Zhou, Qichao and Zhu, Jian},
  title = {A simulation study of a novel spiral volumetric modulated arc therapy for enhanced dose delivery efficiency and quality in radiotherapy},
  journal = {Medical Physics},
  year = {2026},
  volume = {53},
  number = {4},
  doi = {10.1002/mp.70423}
}
Start for free →