EUVIMEDScopri EUVIMED
Open access · CC BY 4.0

Simulation‐free spine palliative radiotherapy enabled by AI‐adapted diagnostic CT

Yiding Han, Alexander Nicola Hanania, Zaid Ali Siddiqui, Vincent Ugarte, Boran Zhou, Abdallah S R Mohamed, Piyush Pathak, Daniel Allen Hamstra, Baozhou Sun

Medical Physics · 2026-03 · 53 (3)

DOI: 10.1002/mp.70366 ↗

At a glance

Journal article in Medical Physics, published online on 2026-02-26. Written by Yiding Han and 8 co-authors. Institution: Radiation Oncology Department, Baylor College of Medicine, TX, USA. 27 references. The full text is freely available (open access, CC BY 4.0). Funded by: Radiation Oncology Institute.

AbstractDati bibliograficiCiteRelated studies

Abstract (original language)

Background

Radiotherapy planning traditionally requires a dedicated simulation CT (sCT), which can introduce delays in initiating treatment. This is particularly impactful in spinal palliative care, where timely treatment is often important for symptom control and prevention of neurological deterioration. Although diagnostic CT (dCT) is frequently available earlier in the workflow, it can lead to geometric and dosimetric inaccuracies when used directly for treatment planning due to discrepancies in patient positioning, vertebral alignment, and table curvature.

Purpose

To develop and evaluate an AI‐based method that transforms dCT into a simulation‐equivalent planning CT (AI‐pCT), enabling a clinically feasible simulation‐free workflow for spinal palliative radiotherapy.

Methods

Two neural networks were trained to correct spine position and body contour using paired dCT–sCT images from 50 patients (42 train/validation, 8 internal tests) in a safety net hospital and externally evaluated on 7 additional academic medical center (AMC) patients. After rigid bone‐based alignment to sCT, dosimetric accuracy was assessed by comparing DVH endpoints (Dmean, Dmax, D95, D99, V100, V107) and DVH Root‐Mean‐Square (RMS) error for plans recalculated on dCT versus AI‐pCT versus sCT. Four radiation oncologists scored image suitability. Significance was evaluated using the Wilcoxon signed‐rank test.

Results

In the safety net cohort, AI‐pCT substantially reduced geometric and dosimetric error relative to dCT (e.g., Dmean error 2.0%→0.57%; RMS DVH error 6.4%→2.2%, all p < 0.05), improved physician plan‐quality ratings from “Acceptable” to “Good–Perfect,” and increased plan‐level clinical goal achievement from 37.5% to 100%. In the AMC cohort, where baseline dCT was already closely aligned to sCT, AI‐pCT produced smaller but still statistically significant gains.

Conclusion

AI‐pCT achieves sCT‐level geometric and dosimetric fidelity without requiring a separate simulation scan, enabling a simulation‐free planning workflow for spinal palliative RT. This approach has the potential to reduce treatment delays and improve access, particularly in resource‐constrained environments.

Authors and institutions

  • Radiation Oncology Department, Baylor College of Medicine, TX, USA.

Funding

  • Radiation Oncology Institute

Cite

APA

Han, Y., Hanania, A. N., Siddiqui, Z. A., Ugarte, V., Zhou, B., Mohamed, A. S. R., Pathak, P., Hamstra, D. A., & Sun, B. (2026). Simulation‐free spine palliative radiotherapy enabled by AI‐adapted diagnostic CT. Medical Physics, 53(3). https://doi.org/10.1002/mp.70366

Vancouver

Han Y, Hanania AN, Siddiqui ZA, Ugarte V, Zhou B, Mohamed ASR, et al. Simulation‐free spine palliative radiotherapy enabled by AI‐adapted diagnostic CT. Medical Physics. 2026;53(3). doi:10.1002/mp.70366

BibTeX
@article{Han2026,
  author = {Han, Yiding and Hanania, Alexander Nicola and Siddiqui, Zaid Ali and Ugarte, Vincent and Zhou, Boran and Mohamed, Abdallah S R and Pathak, Piyush and Hamstra, Daniel Allen and Sun, Baozhou},
  title = {Simulation‐free spine palliative radiotherapy enabled by AI‐adapted diagnostic CT},
  journal = {Medical Physics},
  year = {2026},
  volume = {53},
  number = {3},
  doi = {10.1002/mp.70366}
}
Start for free →