Filling of incomplete sinograms from sparse PET detector configurations using a residual U‐Net
Medical Physics · 2026-03 · 53 (3)
DOI: 10.1002/mp.70293 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, online erschienen am 27.02.2026. Verfasst von Klara Leffler und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mathematics and Mathematical Statistics, Umeå University, Umeå, Sweden. Hauptthemen laut MEDLINE: Positron-Emission Tomography, Image Processing, Computer-Assisted. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Swedish Research Council, Vetenskapsrådet.
Abstract (Originalsprache)
Background
Long axial field‐of‐view PET scanners are becoming increasingly available worldwide for clinical and research nuclear medicine examinations, providing an increased field‐of‐view and sensitivity compared to traditional PET scanners. However, a significant cost is associated with manufacturing the densely packed photodetectors required for the extended‐coverage systems. Despite improved performance allowing ultralow dose or ultrafast scans, the financial barrier remains, limiting clinical utilisation.
Purpose
To mitigate the cost limitations, alternative sparse system configurations with strategically placed inter‐detector gaps have been proposed, allowing an extended field‐of‐view PET design with detector costs similar to a standard PET system, albeit at the expense of image quality.
Methods
To address the challenges posed by sparse detector configurations, particularly the heavy undersampling of PET measurements, we propose a deep sinogram restoration network to fill in the missing sinogram data. The network, a modified Residual U‐Net, is trained end‐to‐end using standard clinical PET scans from a GE Signa PET/MR. The training involves simulating the removal of 50% of the detectors in chessboard patterns of varying sizes, leading to incomplete sinograms with significant count losses (thus retaining only 25% of all lines of response).
Results
The model successfully recovers missing counts in incomplete sinograms, with a mean absolute error consistently below two events per pixel for typical injected radioactivity, outperforming 2D interpolation of incomplete sinograms based on mean absolute error and structural similarity in both sinogram and reconstructed image domain. Notably, the predicted sinograms exhibit a smoothing effect, leading to reconstructed images lacking sharpness in finer details. Despite these limitations, the model demonstrates a substantial capacity for compensating for the undersampling caused by the sparse detector configuration.
Conclusions
This proof‐of‐concept study suggests that sparse detector configurations, combined with deep learning techniques, offer a viable alternative to conventional PET scanner designs. This approach supports the development of cost‐effective, total body PET scanners, allowing a significant step forward in medical imaging technology.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mathematics and Mathematical Statistics, Umeå University, Umeå, Sweden.
- Department of Mathematical Sciences, University of Copenhagen, Copenhagen, Denmark.
- UiT Machine Learning Group, Department of Physics and Technology, UiT The Arctic University of Norway, Tromsø, Norway.
- The PET Imaging Center, University Hospital of North Norway, Tromsø, Norway.
- Nuclear Medicine and Radiation Biology Research Group, Department of Clinical Medicine, UiT The Arctic University of Norway, Tromsø, Norway.
- Department of Diagnostics and Intervention, Oncology, Umeå University, Umeå, Sweden.
Förderung
- Swedish Research Council
- Vetenskapsrådet
Zitieren
APA
Leffler, K., Luppino, L. T., Kuttner, S., Söderkvist, K., & Axelsson, J. (2026). Filling of incomplete sinograms from sparse PET detector configurations using a residual U‐Net. Medical Physics, 53(3). https://doi.org/10.1002/mp.70293
Vancouver
Leffler K, Luppino LT, Kuttner S, Söderkvist K, Axelsson J. Filling of incomplete sinograms from sparse PET detector configurations using a residual U‐Net. Medical Physics. 2026;53(3). doi:10.1002/mp.70293
BibTeX
@article{Leffler2026,
author = {Leffler, Klara and Luppino, Luigi Tommaso and Kuttner, Samuel and Söderkvist, Karin and Axelsson, Jan},
title = {Filling of incomplete sinograms from sparse PET detector configurations using a residual U‐Net},
journal = {Medical Physics},
year = {2026},
volume = {53},
number = {3},
doi = {10.1002/mp.70293}
}
EUVIMED