EUVIMEDSkopri EUVIMED
Crossref

Benchtop 2D multi‐pinhole x‐ray fluorescence imaging system using a high energy resolution pixelated cadmium zinc telluride detector

Taeyun Kim, Mingi Eom, Matthew D Wilson, Diana D Caprotti, Matthew C Veale, Luke B Newman, Seongmoon Jung, Sung-Joon Ye

Medical Physics · 2026-01 · 53 (1)

DOI: 10.1002/mp.70265 ↗

At a glance

Journal article in Medical Physics, published online on 2026-01-07. Written by Taeyun Kim and 7 co-authors. Institution: Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, Republic of Korea. Major MEDLINE topics: Tellurium, Cadmium Compounds, Zinc, Cadmium. Cited 2 times so far (Crossref); 40 references. Funded by: National Research Foundation of Korea.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Background

X‐ray fluorescence (XRF) imaging is a promising modality for quantitative molecular imaging that allows for the in vivo biodistribution detection of specific elements within biological systems. Despite its potential, challenges such as detection limit and scan time have hindered its widespread adoption in preclinical in vivo imaging.

Purpose

This study aims to address these challenges by developing a benchtop 2D multi‐pinhole XRF imaging system with an up‐to‐date cadmium zinc telluride (CZT) detector system without tomographic reconstruction.

Methods

The benchtop 2D multi‐pinhole XRF imaging system was implemented by integrating a High Energy x‐ray Imaging Technology (HEXITEC) 2 × 2 CZT detector system with a lead collimator containing four tungsten pinholes. 140 kV fan beam x‐rays irradiated a small‐animal‐sized polymethyl methacrylate (PMMA) phantom filled with gold nanoparticle (GNP) solutions at concentrations of 0.156, 0.313, 0.625, 1.25, 2.5, and 5.0 mg/mL. A GNP‐loaded phantom with varying concentrations was used to establish a calibration curve relating GNP concentrations to K‐shell XRF photon counts and to evaluate the detection limit of the system.

Results

The multi‐pinhole collimator generated four well‐aligned, nonoverlapping projections, each centered on a CZT module, resulting in a fourfold increase in photon detection efficiency compared with a single‐pinhole collimator. The detector exhibited excellent spectral performance with an energy resolution of 1.38 ± 0.32 keV full width at half maximum (FWHM) at 59.5 keV. As a result, two gold XRF peaks (67.0 and 68.8 keV) were well resolved. Reconstructed XRF images, generated by combining four projections using the maximum likelihood expectation maximization algorithm, showed a strong linear relationship between GNP concentrations and XRF photon counts ( R 2 > 0.99). The benchtop 2D multi‐pinhole XRF imaging system demonstrated in this study achieved a detection limit of 0.105 mg/mL with a scan time of 10 min and an imaging dose of 51.5 cGy.

Conclusions

By successfully integrating a multi‐pinhole collimator with the HEXITEC 2 × 2 CZT detector system, the benchtop 2D multi‐pinhole XRF imaging system substantially improved system sensitivity, achieving a detection limit of 0.1 mg/mL for GNPs, a biologically relevant concentration, in a small‐animal‐sized phantom. This detection limit was attained with a 10‐min scan time and an imaging dose of 51.5 cGy, both within the acceptable range for in vivo imaging applications. These results highlight the potential of the benchtop 2D multi‐pinhole XRF imaging system for preclinical in vivo applications.

Subjects

MeSH terms (MEDLINE)

TelluriumCadmium CompoundsZincCadmiumOptical ImagingSpectrometry, X-Ray EmissionPhantoms, ImagingGoldMetal NanoparticlesAnimals

Author keywords

HEXITECcadmium zinc telluride detectorgold nanoparticlesin vivo molecular imagingx‐ray fluorescence imaging

Substances

TelluriumCdZnTeCadmium CompoundsGoldZincCadmium

Authors and institutions

  • Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, Republic of Korea.
  • Research Institute, T-ROH Inc., Seoul, Republic of Korea.
  • Science and Technology Facilities Council, Rutherford Appleton Laboratory, Harwell Campus, Oxfordshire, UK.
  • Division of Biomedical Metrology, Ionizing Radiation Group, Korea Research Institute of Standards and Science, Daejeon, Republic of Korea.
  • Research Institute for Convergence Science, Seoul National University, Seoul, Republic of Korea.
  • Advanced Institute of Convergence Technology, Seoul National University, Suwon, Republic of Korea.

Funding

  • National Research Foundation of Korea

Cite

APA

Kim, T., Eom, M., Wilson, M. D., Caprotti, D. D., Veale, M. C., Newman, L. B., Jung, S., & Ye, S. J. (2026). Benchtop 2D multi‐pinhole x‐ray fluorescence imaging system using a high energy resolution pixelated cadmium zinc telluride detector. Medical Physics, 53(1). https://doi.org/10.1002/mp.70265

Vancouver

Kim T, Eom M, Wilson MD, Caprotti DD, Veale MC, Newman LB, et al. Benchtop 2D multi‐pinhole x‐ray fluorescence imaging system using a high energy resolution pixelated cadmium zinc telluride detector. Medical Physics. 2026;53(1). doi:10.1002/mp.70265

BibTeX
@article{Kim2026,
  author = {Kim, Taeyun and Eom, Mingi and Wilson, Matthew D and Caprotti, Diana D and Veale, Matthew C and Newman, Luke B and Jung, Seongmoon and Ye, Sung-Joon},
  title = {Benchtop 2D multi‐pinhole x‐ray fluorescence imaging system using a high energy resolution pixelated cadmium zinc telluride detector},
  journal = {Medical Physics},
  year = {2026},
  volume = {53},
  number = {1},
  doi = {10.1002/mp.70265}
}
Start for free →