EUVIMEDOpdag EUVIMED
Crossref

Equivalent constant dose rate as a unifying dose rate concept for FLASH across all beam time structures

Per Rugaard Poulsen, Brita Singers Sørensen, Line Kristensen, Jacob Graversen Johansen

Medical Physics · 2025-12 · 52 (12)

DOI: 10.1002/mp.70205 ↗

At a glance

Journal article in Medical Physics, published online on 2025-12-15. Written by Per Rugaard Poulsen and 3 co-authors. Institution: Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark. Major MEDLINE topics: Radiation Dosage, Proton Therapy. Cited 2 times so far (Crossref); 31 references. Funded by: Danish Cancer Society, Novo Nordisk Foundation, Kræftens Bekæmpelse.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

The FLASH effect has been investigated experimentally using beam modalities with different time structures such as pulsed electron beams and pencil beam scanning (PBS) proton fields. The different beam time structures make direct comparisons between experiments difficult. A biologically founded dose rate concept that is applicable across all beam time structures is highly needed.

Purpose

For any dose delivery with a time‐varying dose rate, we define the equivalent constant dose rate ( eq,const ) as the dose rate that would give the same FLASH sparing effect if the same dose had been delivered with a constant dose rate. This study develops a mathematical framework for eq,const and uses this to investigate eq,const for a range of beam time structures.

Methods

Calculation of eq,const requires a model of the FLASH sparing effect. Here, eq,const was investigated using a phenomenological oxygen enhancement ratio (OER) weighted dose model that has previously been used for successful quantification of the acute skin toxicity variations observed in mice across various proton PBS irradiations. Analytical equations were developed to calculate eq,const for any piece‐wise constant dose rate irradiation and used to determine eq,const for several pulsed beams and PBS fields. eq,const was characterized systematically for pulsed beams and PBS fields, and the ability of eq,const to describe acute skin toxicity occurrence in previous mice experiments was investigated.

Results

For pulsed beams with mean dose rate mean , n pulses, pulse doses up to 5 Gy and pulse repetition times up to 100 ms, eq,const was approximately given by n /( n +1)⋅ mean . eq,const for a 40 Gy PBS transmission proton field with mean = 60 Gy/s previously used for mouse irradiations was 155 Gy/s without repainting, 64 Gy/s with four repaintings, and 7.7 Gy/s when splitting the field into two deliveries separated by 2 minutes. eq,const was 98 Gy/s for spread‐out Bragg peak irradiation without repainting. The occurrence of acute skin toxicity in mice after ∼40 Gy irradiations with various beam time structures, including pulsed electron beams and proton PBS, followed the same trend as function of eq,const , demonstrating its radiobiological relevance. eq,const only depended slightly on the phenomenological OER‐model parameters.

Conclusion

The generally applicable biologically founded dose rate concept eq,const allows direct comparison of FLASH dose rates across all beam time structures.

Subjects

MeSH terms (MEDLINE)

Radiation DosageProton TherapyTime FactorsRadiotherapy DosageAnimalsMiceElectronsSkin

Author keywords

FLASHdose ratenormal tissue sparing

Authors and institutions

  • Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark.
  • Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.
  • Department of Experimental Clinical Oncology, Aarhus University Hospital, Aarhus, Denmark.

Funding

  • Danish Cancer Society
  • Novo Nordisk Foundation
  • Kræftens Bekæmpelse
  • Novo Nordisk Fonden

Cite

APA

Poulsen, P. R., Sørensen, B. S., Kristensen, L., & Johansen, J. G. (2025). Equivalent constant dose rate as a unifying dose rate concept for FLASH across all beam time structures. Medical Physics, 52(12). https://doi.org/10.1002/mp.70205

Vancouver

Poulsen PR, Sørensen BS, Kristensen L, Johansen JG. Equivalent constant dose rate as a unifying dose rate concept for FLASH across all beam time structures. Medical Physics. 2025;52(12). doi:10.1002/mp.70205

BibTeX
@article{Poulsen2025,
  author = {Poulsen, Per Rugaard and Sørensen, Brita Singers and Kristensen, Line and Johansen, Jacob Graversen},
  title = {Equivalent constant dose rate as a unifying dose rate concept for FLASH across all beam time structures},
  journal = {Medical Physics},
  year = {2025},
  volume = {52},
  number = {12},
  doi = {10.1002/mp.70205}
}
Start for free →