Equivalent constant dose rate as a unifying dose rate concept for FLASH across all beam time structures
Medical Physics · 2025-12 · 52 (12)
DOI: 10.1002/mp.70205 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, online erschienen am 15.12.2025. Verfasst von Per Rugaard Poulsen und 3 weiteren Autor:innen. Beteiligte Einrichtung: Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark. Hauptthemen laut MEDLINE: Radiation Dosage, Proton Therapy. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: Danish Cancer Society, Novo Nordisk Foundation, Kræftens Bekæmpelse.
Abstract (Originalsprache)
Background
The FLASH effect has been investigated experimentally using beam modalities with different time structures such as pulsed electron beams and pencil beam scanning (PBS) proton fields. The different beam time structures make direct comparisons between experiments difficult. A biologically founded dose rate concept that is applicable across all beam time structures is highly needed.
Purpose
For any dose delivery with a time‐varying dose rate, we define the equivalent constant dose rate ( eq,const ) as the dose rate that would give the same FLASH sparing effect if the same dose had been delivered with a constant dose rate. This study develops a mathematical framework for eq,const and uses this to investigate eq,const for a range of beam time structures.
Methods
Calculation of eq,const requires a model of the FLASH sparing effect. Here, eq,const was investigated using a phenomenological oxygen enhancement ratio (OER) weighted dose model that has previously been used for successful quantification of the acute skin toxicity variations observed in mice across various proton PBS irradiations. Analytical equations were developed to calculate eq,const for any piece‐wise constant dose rate irradiation and used to determine eq,const for several pulsed beams and PBS fields. eq,const was characterized systematically for pulsed beams and PBS fields, and the ability of eq,const to describe acute skin toxicity occurrence in previous mice experiments was investigated.
Results
For pulsed beams with mean dose rate mean , n pulses, pulse doses up to 5 Gy and pulse repetition times up to 100 ms, eq,const was approximately given by n /( n +1)⋅ mean . eq,const for a 40 Gy PBS transmission proton field with mean = 60 Gy/s previously used for mouse irradiations was 155 Gy/s without repainting, 64 Gy/s with four repaintings, and 7.7 Gy/s when splitting the field into two deliveries separated by 2 minutes. eq,const was 98 Gy/s for spread‐out Bragg peak irradiation without repainting. The occurrence of acute skin toxicity in mice after ∼40 Gy irradiations with various beam time structures, including pulsed electron beams and proton PBS, followed the same trend as function of eq,const , demonstrating its radiobiological relevance. eq,const only depended slightly on the phenomenological OER‐model parameters.
Conclusion
The generally applicable biologically founded dose rate concept eq,const allows direct comparison of FLASH dose rates across all beam time structures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark.
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.
- Department of Experimental Clinical Oncology, Aarhus University Hospital, Aarhus, Denmark.
Förderung
- Danish Cancer Society
- Novo Nordisk Foundation
- Kræftens Bekæmpelse
- Novo Nordisk Fonden
Zitieren
APA
Poulsen, P. R., Sørensen, B. S., Kristensen, L., & Johansen, J. G. (2025). Equivalent constant dose rate as a unifying dose rate concept for FLASH across all beam time structures. Medical Physics, 52(12). https://doi.org/10.1002/mp.70205
Vancouver
Poulsen PR, Sørensen BS, Kristensen L, Johansen JG. Equivalent constant dose rate as a unifying dose rate concept for FLASH across all beam time structures. Medical Physics. 2025;52(12). doi:10.1002/mp.70205
BibTeX
@article{Poulsen2025,
author = {Poulsen, Per Rugaard and Sørensen, Brita Singers and Kristensen, Line and Johansen, Jacob Graversen},
title = {Equivalent constant dose rate as a unifying dose rate concept for FLASH across all beam time structures},
journal = {Medical Physics},
year = {2025},
volume = {52},
number = {12},
doi = {10.1002/mp.70205}
}
EUVIMED