Efficient estimation of gadolinium‐based contrast agent concentration using transient‐state keyhole MR‐STAT

Fei Xu, Edwin Versteeg, Hongyan Liu, Miha Fuderer, Oscar van den Heide, Wybe J M van der Kemp, Cornelis A T van den Berg, Alessandro Sbrizzi

Medical Physics · 2025

DOI: 10.1002/mp.70155 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, 2025. Verfasst von Fei Xu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Computational Imaging Group for MR Diagnostics & Therapy, Center for Image Sciences, UMC Utrecht, Utrecht, the Netherlands. Hauptthemen laut MEDLINE: Contrast Media, Magnetic Resonance Imaging, Gadolinium, Organometallic Compounds. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Nederlandse Organisatie voor Wetenschappelijk Onderzoek (NWO, Netherlands Organisation for Scientific Research).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Fast quantitative MRI (qMRI) techniques have emerged to quantify multiple tissue parameters from a single acquisition in clinically feasible scan times. To integrate fast qMRI techniques into a clinical MRI protocol, one needs to consider imaging after injection of a contrast agent (e.g., dynamic contrast‐enhanced [DCE] imaging). However, fully repeating the multi‐parametric scan after the injection requires lengthy scan times, which are impractical for tracking the contrast agent concentration.

Purpose

This work aimed to develop and validate an accelerated multi‐parametric method capable of estimating the concentration of Gadolinium‐based contrast agents (GBCAs) in a more time‐efficient way.

Methods

We designed an accelerated 2D Magnetic Resonance Spin TomogrAphy in Time‐domain (MR‐STAT) protocol and tested it on a 3T MRI scanner. This is achieved by combining transient‐state acquisitions with Cartesian keyhole‐based acceleration. Based on the reconstructed T 1 values, GBCA concentrations were quantified in phantoms containing water, manganese chloride, and five different concentrations of gadobutrol (Gadovist), ranging from 0.05 to 0.9 mM. Linear regression analysis between the estimated GBCA concentration and the reference values was performed to assess the accuracy. The GBCA concentration quantification method was then applied for synthetic patient data and a hybrid human/phantom study to demonstrate the feasibility of this method.

Results

The accelerated MR‐STAT protocol, with an undersampling factor of 4, provided accurate T 1 , T 2, and GBCA concentration measurements. Estimated GBCA concentrations were in a strong linear relationship with reference values, with a slope and intercept on simple linear regression analysis of 1.034 and 0.009, respectively.

Conclusion

We present a multi‐parametric approach for quantitatively assessing the concentration of gadolinium in vitro and in a hybrid in vivo/in vitro controlled setup using the accelerated MR‐STAT protocol. The concentration of gadobutrol in the range of 0.05–0.9 mM could be measured in a clinically applicable scan time using the proposed method, but needs further in vivo validation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Contrast MediaMagnetic Resonance ImagingGadoliniumOrganometallic CompoundsHumansPhantoms, ImagingTime FactorsImage Processing, Computer-Assisted

Stichwörter der Autor:innen

MR‐STATconcentration estimationcontrast enhancementgadolinium‐based contrast agentquantitative imaging

Substanzen

Contrast MediaGadoliniumgadobutrolOrganometallic Compounds

Autor:innen und Institutionen

  • Computational Imaging Group for MR Diagnostics & Therapy, Center for Image Sciences, UMC Utrecht, Utrecht, the Netherlands.
  • Department of Radiology, University Medical Center Utrecht, Utrecht, the Netherlands.

Förderung

  • Nederlandse Organisatie voor Wetenschappelijk Onderzoek (NWO, Netherlands Organisation for Scientific Research)

Zitieren

APA

Xu, F., Versteeg, E., Liu, H., Fuderer, M., van den Heide, O., van der Kemp, W. J. M., van den Berg, C. A. T., & Sbrizzi, A. (2025). Efficient estimation of gadolinium‐based contrast agent concentration using transient‐state keyhole MR‐STAT. Medical Physics. https://doi.org/10.1002/mp.70155

Vancouver

Xu F, Versteeg E, Liu H, Fuderer M, van den Heide O, van der Kemp WJM, et al. Efficient estimation of gadolinium‐based contrast agent concentration using transient‐state keyhole MR‐STAT. Medical Physics. 2025. doi:10.1002/mp.70155

BibTeX
@article{Xu2025,
  author = {Xu, Fei and Versteeg, Edwin and Liu, Hongyan and Fuderer, Miha and van den Heide, Oscar and van der Kemp, Wybe J M and van den Berg, Cornelis A T and Sbrizzi, Alessandro},
  title = {Efficient estimation of gadolinium‐based contrast agent concentration using transient‐state keyhole MR‐STAT},
  journal = {Medical Physics},
  year = {2025},
  doi = {10.1002/mp.70155}
}
Kostenlos starten →