Journal article in Medical Physics, 2025. Written by Ping Lin Yeap and 5 co-authors. Institution: Department of Oncology, University of Cambridge, Cambridge, UK. Major MEDLINE topics: Cone-Beam Computed Tomography, Signal-To-Noise Ratio, Models, Statistical, Image Processing, Computer-Assisted. Cited 1 times so far (Crossref); 48 references. The full text is freely available (open access, CC BY 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

In adaptive cancer radiotherapy, treatment plans were periodically re‐optimised according to anatomical variations, with the goal of maintaining or improving clinical outcomes. This required high‐quality in‐room imaging for daily monitoring, tumour/organ segmentation and dose evaluation. However, in‐room cone‐beam computed tomography (CBCT) images suffered from inaccurate Hounsfield Unit (HU) values and poor image quality due to higher artifact presence and lower signal‐to‐noise ratio. While CBCT‐to‐CT generation models have shown promising results, many conventional networks require large datasets for training.

Purpose

To address this, we proposed a denoising diffusion probabilistic model (DDPM) with a modified sampling process to enable few‐shot synthetic CT (sCT) generation from CBCT images.

Methods

We used a denoising diffusion probabilistic model trained on rigidly registered CT‐CBCT image pairs in our approach, without requiring deformable registrations. Our model was trained on 25 patients from a head‐and‐neck cancer cohort at our institution, and validated and tested on separate sets of seven and eight patients. Our sampling method leveraged channel‐ and noised‐conditioning, demonstrating high‐quality sCT generation with limited training data. By adding noise to guiding CBCT images during sampling, we exploited the convergence of CBCT and planning CT (pCT) representations in latent space. This allowed sampling from a noisy representation of the data, achieving sCTs with high fidelity.

Results

Evaluation on a head‐and‐neck (H&N) cancer dataset showed that sCTs outperformed CBCTs, reducing masked mean absolute error (MAE) from 131 ± 17 HU to 49 ± 7 HU, and improving peak signal‐to‐noise ratio (PSNR) from 20.0 ± 0.9 dB to 22.9 ± 1.1 dB and normalised cross‐correlation (NCC) from 0.93 ± 0.01 to 0.96 ± 0.01. We further evaluated the method's generalisability on phantoms and publicly available patient datasets. Without retraining, the model achieved moderate improvements over CBCT (e.g., masked MAE 87 ± 17 HU, PSNR 19.4 ± 1.7 dB, NCC 0.93 ± 0.04) on the external H&N dataset. However, after retraining on 27 in‐distribution patient cases, the model achieved comparable performance to our internal dataset, with MAE 48 ± 12 HU, PSNR 22.2 ± 2.5 dB, and NCC 0.95 ± 0.03. We also extended the model to the pelvis site, achieving similarly strong results (masked MAE 44 ± 9 HU, PSNR 21.9 ± 2.1 dB, NCC 0.96 ± 0.03), demonstrating the feasibility of our method across multiple anatomical sites. Visual inspections showed improved image quality, significantly reduced artifacts, and better anatomical preservation in sCTs. Clinician evaluations revealed a higher preference to use sCTs over pCTs for fractional evaluation.

Conclusions

Our work offered a practical, data‐efficient and site‐robust solution for clinics to generate high‐fidelity sCTs, facilitating CBCT‐based dose evaluation and plan adaptation in adaptive radiotherapy workflows.

Subjects

MeSH terms (MEDLINE)

Cone-Beam Computed TomographySignal-To-Noise RatioModels, StatisticalImage Processing, Computer-AssistedHumansDiffusionHead and Neck Neoplasms

Author keywords

adaptive radiotherapycone‐beam CTdiffusion modelsynthetic CT generation

Authors and institutions

  • Department of Oncology, University of Cambridge, Cambridge, UK.
  • Department of Physics, University of Cambridge, Cambridge, UK.
  • Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong, China.
  • Department of Medical Physics, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK.
  • Department of Oncology, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK.

Cite

APA

Yeap, P. L., Du, X., Zhou, M., Hoole, A., Barnett, G. C., & Jena, R. (2025). Few‐shot CBCT‐based synthetic CT generation with denoising diffusion probabilistic model. Medical Physics. https://doi.org/10.1002/mp.70126

Vancouver

Yeap PL, Du X, Zhou M, Hoole A, Barnett GC, Jena R. Few‐shot CBCT‐based synthetic CT generation with denoising diffusion probabilistic model. Medical Physics. 2025. doi:10.1002/mp.70126

BibTeX
@article{Yeap2025,
  author = {Yeap, Ping Lin and Du, Xin and Zhou, Meng and Hoole, Andrew and Barnett, Gillian C and Jena, Rajesh},
  title = {Few‐shot CBCT‐based synthetic CT generation with denoising diffusion probabilistic model},
  journal = {Medical Physics},
  year = {2025},
  doi = {10.1002/mp.70126}
}
Start for free →